Possible causes of burner faults
Error
Possible cause
code
10
Feeder does not supply enough of pellets.
Empty pellet container.
Faulty ignition fuse.
Faulty ignition spiral.
Photocell needs to be cleaned.
11
Feeder does not supply enough of pellets.
Empty pellet container.
Faulty ignition fuse.
Faulty ignition spiral.
Photocell needs to be cleaned.
12
Short circuit or other fault of the photocell.
13
Too high temperature in the boiler room.
14
Faulty sensor of thermostat
15
Faulty sensor of thermostat
16
Faulty circuit board
18
Ventilator runs, while the burner is in pause mode. Replace the circuit board.
19
Ventilator does not run, when it should.
20
Ventilator runs too slowly
21
First ignition trial failed
22
Pellet feeder missing
23
Incorrect pellet supply
24
Incorrect amount of pellets supplied.
Faulty photocell
25
Cleaning does not work
26
Cleaning is slow
63
Actions to correction
Set the pellet ration.
Fill the container.
Replace the fuse. (6.3 A).
Replace the spiral. (48 Ώ +/− 5 %).
Clean the photocell.
Set the pelletration.
Fill the container.
Replace the fuse. (6.3 A).
Replace the spiral. (48 Ώ +/− 5 %).
Clean the photocell.
Replace the photocell.
Prevent from the heat leakage.
Replace the sensor.
Replace the sensor.
Replace the circuit board.
Change the ventilator fuse
(800 mA); check the connections;
replace the ventilator
Clean the ventilator; replace the
ventilator
Set the pellet ration.
Connect the pellet feeder
Set pellet ration.
Set the pellet ration.
Replace the photocell.
Check the connection between
the circuit board of scraper and
the main circuit board.
Clean the grate