Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Mitsubishi Manuals
Controller
MELSEC QCPU
Programming manual
I/O Refresh Instructions; I/O Refresh (Rfs, Rfsp) - Mitsubishi MELSEC QCPU Programming Manual
Programmable logic controller
Hide thumbs
Mitsubishi
MELSEC QCPU
Programming Manual
1
2
3
4
Table Of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
page
of
285
Go
/
285
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
6 BASIC INSTRUCTIONS
6.7 I/O Refresh Instructions
6.7.1 I/O Refresh (RFS, RFSP)
Internal Devices
Set
(System, User)
Data
Bit
Word
S
(Only X, Y)
n
[Instruction Symbol] [Execution Condition]
RFS
RFSP
[Set Data]
Set Data
S
n
[Functions]
(1) Refreshes only the device being scanned during a scan, and functions to fetch input from
external sources or to output data to an output module.
(2) Fetching of input from or sending output to an external source is conducted in batch only after
the execution of an END instruction, so it is not possible to output a pulse signal to an outside
source during the execution of a scan.
When a refresh operation is conducted, inputs (X) or outputs (Y) of the device numbers
relevant to the program being executed are forcibly refreshed, so it is possible to output a
pulse signal to an external source during a scan.
6 - 111
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MELSECNET/10(H)
File
Direct J \
Register
Bit
Command
Command
Head device number of the device that will conduct refresh operation
Number of points to be refreshed
QCPU
PLC CPU
Basic
High Performance
Usable Devices
Special
Function
Module
Word
U \G
RFS
RFSP
Meaning
MELSEC-Q/QnA
QnA
Process CPU
Index
Constant
Register
Other
K, H
Zn
n
S
n
S
Data Type
Bit
BIN 16 bits
6 - 111
Q4AR
Table of
Contents
Previous
Page
Next
Page
1
...
261
262
263
264
Advertisement
Table of Contents
Related Manuals for Mitsubishi MELSEC QCPU
Controller Mitsubishi MELSEC-Q Series User Manual
(814 pages)
Control Unit Mitsubishi MELSEC QD75P User Manual
Positioning module (768 pages)
Controller Mitsubishi Melsec-Q Series User Manual
(612 pages)
Controller Mitsubishi MELSEC Q Series Reference Manual
With melsec communication protocol (532 pages)
Control Unit Mitsubishi MELSEC L Series User Manual
Communication module (396 pages)
Controller Mitsubishi MELSEC-L series Programming Manual
(390 pages)
Controller Mitsubishi MELSEC-Q Series User Manual
Cc-link system master/local module, mitsubishi programmable logic controller (312 pages)
Controller Mitsubishi MELSEC-Q Series User Manual
Positioning module with built-in counter function (296 pages)
Controller Mitsubishi MELSEC-Q Series User Manual
Programmable controller multiple cpu system (280 pages)
Controller Mitsubishi MELSEC-Q Series Programming Manual
(236 pages)
I/O Systems Mitsubishi MELSEC-Q Series User Manual
Channel isolated thermocouple input module, gx-configurator-ti sw1d5c-qtiu-e, programmable controller (218 pages)
Controller mitsubishi MELSEC Q series User Manual
Programmable controller (204 pages)
Controller Mitsubishi MELSEC-Q Series User Manual
Programmable controller (142 pages)
Controller Mitsubishi MELSEC-Q Series Programming Manual
Mitsubishi programmable controller (108 pages)
Controller Mitsubishi MELSEC Q Series User Manual
High-speed counter module (108 pages)
Controller Mitsubishi MELSEC-Q Series User Manual
Mes interface module (20 pages)
Related Content for Mitsubishi MELSEC QCPU
MELSEC-A Series Link Refresh Instructions
Mitsubishi MELSEC-A Series
MELSEC-Q Series I/O Refresh Instructions 6.7.1 I/O Refresh
Mitsubishi MELSEC-Q Series
MELSEC Q Series I/O Refresh Instructions
Mitsubishi MELSEC Q Series
MELSEC-Q/L I/O Refresh Instructions
Mitsubishi MELSEC-Q/L
MELSEC-A AJ71PT3 1/0 Refresh
Mitsubishi MELSEC-A AJ71PT3
MELSEC-A AJ35PTC-CNV Handling Instructions
Mitsubishi MELSEC-A AJ35PTC-CNV
MELSEC-L Series Auto Refresh
Mitsubishi MELSEC-L Series
MELSEC AJ65BT-R2 Safety Instructions
Mitsubishi MELSEC AJ65BT-R2
MELSEC QS Series Types Of Instructions
Mitsubishi MELSEC QS Series
MELSEC Q4ARCPU Wiring Instructions
Mitsubishi MELSEC Q4ARCPU
MELSEC Q Series Auto Refresh
Mitsubishi MELSEC Q Series
MELSEC-F FX 3U Series Instructions For Connecting Input Devices
Mitsubishi MELSEC-F FX 3U Series
AJ65BT-D62 Handling Instructions
Mitsubishi AJ65BT-D62
A1SJH Mounting Instructions
Mitsubishi A1SJH
MELSEC-Q Series Communication By Auto Refresh Using Cpu Shared Memory
Mitsubishi MELSEC-Q Series
MELSEC-Q Series Link Device Refresh Setting
Mitsubishi MELSEC-Q Series
This manual is also suitable for:
Melsec qnacpu
Melsec q mode
Melsec q series
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL