6 BASIC INSTRUCTIONS
[Operation Errors]
(1) In the following cases an operation error occurs and the error flag goes ON.
• The entire character string linked from the device number designated by
number of the relevant device cannot be stored.
• The storage device numbers for the character strings designated by
those for
[Program Example]
(1) The following program links the character string stored from D10 to D12 with the character
string "ABCD" when X0 is ON, and stores them in D100 onwards.
[Ladder Mode]
b15 - - - b8
D10
62
(b)
H
64
(d)
D11
H
00
D12
H
6 - 52
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
.
D
b7 - - - - b0
61
(a)
H
+
63
(c)
"ABCD"
H
65
(e)
H
[List Mode]
Steps
Instruction
b15 - - - b8 b7 - - - - b0
D100
62
64
D101
D102
41
D103
43
D104
Automatically stores "00
"