6 BASIC INSTRUCTIONS
[Program Example]
(1) The following program turns Y0 and Y1 ON and OFF once each second (flicker) when X20 is
ON. (Uses the 100ms timer)
[Ladder Mode]
6 - 121
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
X20
M1,Y0
M2,Y1
M3
1 s
1 s
[List Mode]
Steps
Instruction
MELSEC-Q/QnA
Device
6 - 121