Features; Specifications - Yoshitake GP-1200 Installation And Operation Manual

Pressure reducing valve
Table of Contents

Advertisement

1. Features

GP-1000 Series pressure reducing valves for steam are pilot-operated valves which can be used with
confidence for small to large flow rate, in a host of applications ranging from building utilities systems,
air-conditioning systems, and factory systems, etc.GP-1200 and 1210 models can be used as pneumatic,
remote type valves, making them well suited for systems where the pressure setting is frequently
changed, or for centralized control system.

2. Specifications

Model
Connection
Nominal size
Application
Inlet pressure
Reduced pressure
Loading air pressure
Min. differential pressure
Max. pressure reducing ratio
Max. temperature
Valve seat leakage
Body
Valve
Valve seat
Piston/Cylinder
Gasket
Body hydraulic test
l Stainless steel main components (piston & cylinder) are also available. (GP-1200S,1210S)
l Stainless steel type is also available for GP-1200 [15-50A]. (GP-1200SS: Wetted parts stainless steel)
 Caution
(1) Please collate with attached nameplate and specification of ordered model.
※Please consult factory in case they do not match each other.
GP-1200
Flanged (JIS 10K FF)
15~100A
0.1~1.0 MPa
0.05~0.9 MPa
90% or less of inlet pressure (gauge pressure)
See the "Standard loading pressure-setting pressure chart line". (P.3)
0.01% or less of rated flow
Ductile cast iron
Stainless steel
Stainless steel
Brass or Bronze
Non asbestos
‑1‑
GP-1210
JIS Rc Screw
15~50A
Steam
0.05 MPa
20:1
220℃
2.0 MPa
■EPDT-101■