2.2

Technical data

Technical data
Technology
Number of channels
IO-Link interfaces
Field voltage
Connection
Data transfer rates
Cable length
Power supply
Supply current for devices
Current consumption from K-bus
Current consumption from power contacts
Nominal voltage
Electrical isolation
Weight
K-bus bit width
Configuration
Permissible ambient temperature during
operation
Permissible ambient temperature during
storage
Permissible relative humidity
Mounting [} 12]
Vibration / shock resistance
EMC resistance burst / ESD
Protection class
Installation position
Approval
KL6224
KL6224
IO-Link
4
4
24 V
(via power contacts)
DC
3-wire, HD terminal [} 16]
4.8 kBaud, 38.4 kBaud and 230.4 kBaud
max. 20 m
via K-Bus and power contacts
500 mA per device
typ. 85 mA
not specified
24 V
(-15 %/+20 %)
DC
500 V (IO-Link / K-bus)
app. 60 g
depends on the process image
via fieldbus parameter interface, DP-V1 or Bus Coupler
via Configuration software KS2000
0°C ... +55°C
-25°C ... +85°C
95 %, no condensation
on 35 mm mounting rail conforms to EN 60715
conforms to EN 60068-2-6 / EN 60068-2-27
see also installation instructions [} 14] for enhanced
mechanical load capacity
conforms to EN 61000-6-2 / EN 61000-6-4
IP20
Variable
CE, cULus