Electrical Installation

4.8.1 Control Terminal Types

Illustration 4.7 and Illustration 4.8 show the removable
frequency converter connectors. Terminal functions and
default settings are summarised in Table 4.3 and Table 4.4.
4
4
Illustration 4.7 Control Terminal Locations
Illustration 4.8 Terminal Numbers
Connector 1 provides 4 programmable digital
inputs terminals, 2 additional digital terminals
programmable as either input or output, a 24 V
DC terminal supply voltage, and a common for
optional customer supplied 24 V DC voltage. FC
302 and FC 301 (optional in A1 enclosure) also
provide a digital input for STO (Safe Torque Off)
function.
Connector 2 terminals (+)68 and (-)69 for RS-485
serial communication connection
Connector 3 provides 2 analog inputs, one
analog output, 10 V DC supply voltage, and
commons for the inputs and output
Connector 4 is a USB port available for use with
the MCT 10 Set-up Software
16
VLT
4
1
12 13 18 19 27 29 32 33 20 37
2
3
61 68 69
39 42 50 53 54 55
®
AutomationDrive FC 301/302 Operating Instructions
Terminal Parameter
12, 13
18
19
32
1
33
27
29
20
37
39
42
50
53
54
55
Table 4.3 Terminal Description Digital Inputs/Outputs,
Analog Inputs/Outputs
MG33AN02 - Rev. 2013-09-06
Terminal description
Default
setting
Description
Digital inputs/outputs
-
+24 V DC
24 V DC supply
voltage for digital
inputs and external
transducers. Maximum
output current 200
mA (130 mA for FC
301) for all 24 V loads.
5-10
[8] Start
5-11
[10] Reversing
5-14
[0] No
Digital inputs.
operation
5-15
[0] No
operation
5-12
[2] Coast
For digital input or
inverse
output. Default setting
5-13
[14] JOG
is input.
-
Common for digital
inputs and 0 V
potential for 24 V
supply.
-
Safe Torque
Safe input. Used for
Off (STO)
STO.
Analog inputs/outputs
-
Common for analog
output
6-50
[0] No
Programmable analog
operation
output. 0-20 mA or
4-20 mA at a
maximum of 500 Ω
-
+10 V DC
10 V DC analog
supply voltage for
potentiometer or
thermistor. 15 mA
maximum
6-1*
Reference
Analog input. For
voltage or current.
6-2*
Feedback
Switches A53 and A54
select mA or V.
-
Common for analog
input

Hide quick links: