Application Set-up Examples
6.1.8 Mechanical Brake Control
FC
+24 V
12
+24 V
13
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
D IN
37
+10 V
50
A IN
53
A IN
54
COM
55
A OUT
42
COM
39
01
02
03
04
05
06
Table 6.14 Mechanical Brake Control
1-76
Current
Speed
1-71
Start (18)
Start
reversing (19)
Relay output
Open
Closed
Illustration 6.4 Mechanical Brake Control
®
VLT
AutomationDrive FC 301/302 Operating Instructions
Parameters
Function
Setting
5-40 Function
[32] Mech.
Relay
brake ctrl.
5-10 Terminal 18
[8] Start*
Digital Input
5-11 Terminal 19
[11] Start
Digital Input
reversing
1-71 Start Delay
0.2
1-72 Start
plus
[5] VVC
/
Function
FLUX
Clockwise
1-76 Start
I
m,n
Current
2-20 Release
App.
Brake Current
dependent
2-21 Activate
Half of
Brake Speed
nominal slip
[RPM]
of the motor
*=Default Value
Notes/comments:
Time
2-21
1-71
2-21