Specifications
Environmental specifications
Specification
System inlet temperature (standard operating
1
support
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper
limit and rate of change might be limited by the type and number of options installed. Under standard operating support, a
fan fault or the ambient temperature exceeding 30°C (86°F) might result in reduced system performance issue.
Mechanical specifications
Specification
Dimensions
Height
Depth, chassis with 1U server node
Depth, chassis with 2U server node
Width
Weight (approximate values)
Weight, minimum
Weight, maximum for 1U system
Weight, maximum for 2U system
1
The weight values are for a chassis with server nodes and server blanks installed.
54
Specifications
1
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
—
8.73 cm (3.44 in)
85.95 cm (33.84 in)
89.38 cm (35.19 in)
44.81 cm (17.64 in)
—
17.21 kg (37.94 lb)
22.65 kg (49.94 lb)
19.62 kg (43.25 lb)