Technical Data - gledhill benchmark BoilerMate A-Class OV Series Design, Installation And Servicing Instructions

An open vented central heating and mains pressure hot water supply system
Table of Contents

Advertisement

Model
BMA 125 OV
Weight (empty)
Weight (full)
DHW Pump
Grundfos UPR 15/50 Grundfos UPR 15/50
Heating Pump
Grundfos UPS 15/50
Boiler Pump
Grundfos UPS 15/50
Primary/heating
pipe connections
MCW & DHW pipe
connections
Cold feed/expansion
connection
Safety open vent
connection
Primary return
(for summer use
bathroom towel rail)
Maximum summer
towel rail load
Drain connection
Maximum Head
10 meters
Hot water flow rate
(l/m) up to
Max heating system
size
'Switch'
Typical Dwelling Types
Bedrooms
Bathrooms
En-suite shower
Notes:-
1.
The BoilerMate 225 appliance is suitable for use in large properties because it produces the same'peak hour output'as a typical 350-
400 litre unvented cylinder. For properties requiring the BMA 225 the incoming main should be a minimum of 32mm MDPE with
a pressure of not less than 2 bar dynamic and an adequate flow in line with the pipe sizing calculations. In many cases, properties
of this size will benefit from having 2 smaller sized appliances located adjacent to the areas of peak hot water use. This will allow
2 heating zones to be provided and remove the need to provide trace heating on the hot water system.
2.
A plastic feed and expansion cistern will be supplied separately including ballvalve, float and overflow fitting.
3.
The flow rates are based on a 35°C temperature rise and assume normal pressure and adequate flow to the appliance. The actual
flow rate from the appliance is automatically regulated to a maximum of 28 litres/min.
4.
Unit is supplied on a 100mm high installation base.
5.
The domestic hot water outlet temperature is automatically regulated to approximately 52°C at the bath flow rate of 18 litres/min
recommended by BS 6700. The temperature is not user adjustable.
BMA 145 OV
45
47
177
187
Grundfos UPS 15/50
Grundfos UPS 15/50
22mm
22mm
22mm
22mm
22mm
22mm
22mm
22mm
15mm
15mm
0.15kW
0.75kW
R ½"
R ½"
10 meters
35
35
12 kW
17 kW
6 kW
6 kW
1-3
2-3
1
1
1
2
1.0 DESIGN

1.2 TECHNICAL DATA

BMA 185 OV
BMA 210 OV
50
197
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPS 15/50
Grundfos UPS 15/60
Grundfos UPS 15/50
Grundfos UPS 15/60
22mm
28mm
22mm
22mm
22mm
22mm
22mm
22mm
15mm
15mm
1.00kW
1.25 kW
R ½"
R ½"
10 meters
10 meters
35
20 kW
25 kW
6 kW
6 kW
2-4
2
1
1
4
Page 5
BMA 225 OV
51
56
215
244
Grundfos UPR 15/50
Grundfos UPS 15/60
Grundfos UPS 15/60
28mm
22mm
22mm
22mm
15mm
1.5 kW
R ½"
10 meters
35
35
30 kW
6 kW
3-5
4-6
2
1
3
2
4
2
4
0