Design; Technical Data - gledhill BoilerMate A-Class OV SOL Series Design, Installation & Servicing Instructions

Table of Contents

Advertisement

Table 1.1
Model
Weight (empty)
Weight (full)
DHW pump
Heating pump
Boiler pump
Solar pump
Primary/heating pipe
connections
MCW & DHW pipe
connections
Cold feed/expansion
connection
Safety open vent
connection
Drain connections
Maximum head
Hot water flow rate (l/m)
up to
Max heating system size
'Switch'
Typical Dwelling Types - Model Selection
Bedrooms
Bathrooms
En-suite shower
Max. floor area (m
)
2
Notes:-
1. For larger properties the incoming main should be a minimum of 32mm MDPE
with a pressure of not less than 2 bar dynamic and an adequate flow in line with
the pipe sizing calculations.
2. The flow rates are based on a 35°C temperature rise and assume normal pressure
and adequate flow to the appliance. The actual flow rate from the appliance is
automatically regulated to a maximum of 28 litres/min.
3. Unit is supplied on a 100mm high installation base.
4. The domestic hot water outlet temperature is automatically regulated to
approximately 52°C (± 2°c) at the bath flow rate of 18 litres/min recommended by
BS 6700. The temperature is not user adjustable.
5. The suggestions under Model Selection for any appliance size are maximums, and
in the same way as the criteria used for sizing the water distribution systems, are
based on a typical diversity of use. Therefore it will be impractical to expect the
appliance or the water distribution system to be able to support simultaneous use
of the sanitary fittings shown.

Technical Data

BMA 215
BMA 225
OV SOL
OV SOL
67
67
231
255
Grundfos UPS 15/50
Grundfos UPS 15/50
22mm
8kW
10kW
2-3
2-4
1
2
2
1
80
100
Page 7
BMA 235
BMA 245
OV SOL
OV SOL
75
85
300
363
Grundfos UPR 15/50
Grundfos UPR 15/60 Solar
22mm
15mm
22mm
Rc ½
6 metres
35
13kW
17kW
6kW
3-4
3-5
2
1
2
2
4
3
130
170
6. In projects requiring Building Regulations
approval, the maximum floor area figure
must not be exceeded to ensure compliance
with ADLI requirements. However, final
selection should be made on the basis of the
minimum model (appliance size) that meets
all the criteria i.e. heating load/number of
bathrooms and shower rooms/floor area.

DESIGN

BMA 265
BMA 285
OV SOL
OV SOL
95
106
405
466
Grundfos UPS 15/60
Grundfos UPS 15/60
28mm
22kW
28kW
4-5
4-6
1
2
1
5
4
6
220
280
3
3