DESIGN
The minimum clear
opening in front of
the appliance to be
at least the same as
the depth of the
appliance
plus 50mm.
**To comply with the
access requirements of
the Water Regulations.
F&E cistern
*Minimum access /
maintenance access
above the appliance
B
case.
BoilerMate A-Class
OV SOL
E
The cupboard door
opening will need to
Maintenance
take into account the
access
various sizes of
appliances.
Model
BMA 215
OV SOL
BMA 225
OV SOL
BMA 235
OV SOL
BMA 245
OV SOL
BMA 265
OV SOL
BMA 285
OV SOL
The above dimensions do not include the
100mm high installation base.

Minimum Cupboard Dimensions

Model
BMA 215
OV SOL
BMA 225
OV SOL
BMA 235
OV SOL
BMA 245
OV SOL
BMA 265
OV SOL
BMA 285
OV SOL
The above dimensions include the 100mm
high installation base. In the case of the 215-
225 models, they assume the F&E cistern is in
the same cupboard. However, for the 235-285
models they allow space for installation/
maintenance of the appliance only.
Note: With the 235-285 models, space will
be required, in addition to the above, for two
feed and expansion cisterns (280mm wide x
420mm deep x 300 high), which are provided
separately, complete with a ballvalve and
overflow connector. 350mm will still be required
above the cisterns to meet the minimum access
requirementsof the Water Regulations for the
ballvalve.
Figure 1.4
Page 8

Appliance Dimensions

Height
Width
Depth
(A)
(B)
(C)
1330
560
620
1330
560
620
1575
560
620
1575
610
690
1575
640
715
1485
710
785
Height
Width
Depth
(D)
(E)
(F)
2080
660
630
2080
660
630
2025
660
630
2025
710
700
2025
740
725
1935
810
795