An open vented central heating and mains pressure hot water supply system
Table of Contents

Advertisement

Sensor
Sensor
S1
T Overheat 1
S2
T Overheat 2
S3
T DHW in
S4
T DHW out
S5
T Tank bottom
S6
T Tank middle
Sensor Control Set Points
Display
S1
Middle store sensor on
S2
Middle store sensor off
S3
DHW in
S4
DHW out
S5
Bottom store sensor on
S6
Bottom store sensor off
Common Fault Codes
Code
10
Overheat error
30
Phase error
33
Appliance selection
37
S1 overheat 1 open
40
I.D. resistor open
41
S4 sensor open
42
S5 sensor open
43
S6 sensor open
44
S2 overheat 2 open
Any other code displayed should be checked against the full chart
Sensors used in BoilerMate A-Class
Connector J9 pins
6 & 14
Top of store in dry pocket (S1 & S2 are in single housing)
2 & 10
3 & 11
In cold water inlet pipe (Wet i.e. direct)
4 & 12
In hot water outlet pipe (Wet i.e. direct)
5 & 13
Bottom of store in dry pocket for store charging
1 & 9
Middle of store in dry pocket for store charging
Sensor
Code
45
S1 overheat 1 shorted
48
I.D. resistor shorted
49
S4 sensor shorted
50
S5 sensor shorted
51
S6 sensor shorted
52
S2 overheat 2 shorted
1.0 DESIGN
1.2 TECHNICAL DATA
Sensor Tempature Readings
Details of the various sensors S1-S6 used in
the BoilerMate A-Class are shown opposite.
The sensor reference i.e. S1 and the actual
temperature at that sensor flash alternately on
the display when selected.
Location
Control Set Points
The sensor control set points are shown
Temp
opposite. PLEASE NOTE THAT THE DISPLAY
68
S1 - S6 IS NOT THE SAME AS THE SENSOR
REFERENCE.
77
35
55
60
70
Fault Codes
Fault code locations are numbered C0 - CF
and c0 - cF.
CO/cO locations hold the latest fault recorded.
A code of FF indicates that the fault location
is empty.
If a sensor is faulty instead of a temperature
it will show E1 if open circuit and E2 if short
circuit.