(3) Disconnect the key PCB flat cable from the panel PCB ASSY and release it from the securing fixtures.
(4) Remove the six taptite cup B M3x10 screws. Release the three hooks to remove the LCD
presser base from the panel unit.
Taptite cup B M3x10
Key PCB flat cable
Panel PCB ASSY
Hook
HARNESS ROUTING: Refer to
Assembling Note:
• When connecting the key PCB flat cable, fold it as shown in the figure below.
Mountain fold
33
Panel
PCB
side
Reinforcing
plate
Mountain fold at the end of reinforcing plate.
Fig. 3-28
"4. Panel
unit".
Key PCB flat cable
°
45
Fig. 3-29
3-32
Taptite cup B M3x10
LCD presser base
Hooks
Key PCB ASSY
Panel unit
Confidential