FluidAqua Mobil - FAM 10/15-P
FCU plug missing (only in conjunction with accessory FCU)
1.
2.
3.
4.
5.
->a. Yes
6.
->b. No
7.
8.
->a. Yes
9.
->b. No
10.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
Description
Fault:
"FCU plug missing"
Cause: Connection cable to the FluidControl Unit FCU is not
connected.
Establish the connection with a connection cable
To reset the failure, press the RESET key
Fault appears again?
Check connection cable and plug; replace if necessary
Fault appears again?
The failure is repaired.
-> proceed to Step 7.
-> proceed to Step 10.
-> proceed to Step 4.
-> proceed to Step 10.