Sign In
Upload
Manuals
Brands
HYDAC International Manuals
Control Unit
FCU 1000 Series
HYDAC International FCU 1000 Series Manuals
Manuals and User Guides for HYDAC International FCU 1000 Series. We have
2
HYDAC International FCU 1000 Series manuals available for free PDF download: Operating And Maintenance Instructions Manual
HYDAC International FCU 1000 Series Operating And Maintenance Instructions Manual (64 pages)
FluidControl Unit
Brand:
HYDAC International
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Contents
3
Table of Contents
3
What's New - Document History
5
Preface
6
Customer Service
7
Modifications to the Product
7
Warranty
7
Using the Documentation
8
1 General Safety Precautions
9
Obligations and Liability
9
Explanation of Symbols and Warnings, Etc
10
Basic Symbols
10
Proper/Designated Use
10
Improper Use
11
Informal Safety Precautions
11
How to Behave in Case of Emergency
11
Safety Measures to be Followed in Normal Operation
11
Electrical Hazards
12
Maintenance, Servicing and Troubleshooting
12
Modifications to the FCU
12
Cleaning the FCU and Disposal of the Media and Agents Used
12
2 Transportation/Package/Storage
13
Packing / Transportation
13
Storage
13
Storage Conditions
13
3 Decoding the Model Code Label
13
4 Checking the Scope of Delivery
14
5 Using the FCU
15
Mode of Function
16
Operation Panel
18
Dimensions
19
Hydraulic Schematic
19
6 Preparing the FCU
20
Attaching OUTLET Quick-Action Coupling
20
Hydraulic Connection of the FCU
20
Connection at the Measurement Point up to Max. 45 Bar
21
Connection at the Measurement Point with 45
23
Selecting the Measurement Point
25
Connection at the Measurement Point - Non-Pressurized Tank
26
Electrical Connection of the FCU
27
7 Operating the FCU
28
Display and Keypad Elements
28
Measured Variables
29
Measured Variable "ISO
29
Measured Variable "SAE
29
Measured Variable "NAS
29
Measured Variable "Water Saturation
29
Measured Variable "Temperature
30
Service Variables
30
Service Variables "Flow
30
Service Variables "Drive
30
Switching the Display
31
Activate / Deactivate Keypad Lock
31
Modes and Menus
32
Power up Menu
32
Measuring Menu ISO / SAE
33
Menu Structure ISO / SAE
34
Measuring Menu ISO / NAS
34
Menu Structure ISO / NAS
35
8 Performing a Measurement
35
Restrictions Pertaining to Use
35
9 Dismantling the FCU
36
10 FCU Interfaces
37
DATA (HYDAC Sensor Interface - HSI)
37
10.1.1 Connecting the FCU with HMG 510 / HMG 3000
38
Connecting the FCU with CSI-B-2
39
Bluetooth Interface
40
10.2.1 Installing the Bluetooth USB Adaptor
41
10.2.2 Connecting the FCU Via Bluetooth
41
Measurement Value Readouts with Flumos
41
11 Conducing Maintenance
42
Cleaning the FCU
42
Rinsing the FCU
42
11.2.1 Performing a Rinsing
42
Cleaning the Suction Strainer
43
Checking the High Pressure Adaptor
47
11.4.1 Cleaning / Changing the Strainer in the High Pressure Adaptor
47
11.4.2 Cleaning / Changing the Strainer in the High Pressure Adaptor
48
Disposing of the FCU
48
12 FCU Status Messages
49
Status LED / Display
49
Error Message
49
Exceptions Errors
50
13 Spare Parts
51
Accessories
53
14 Technical Data
54
15 ISO 4406 / SAE as 4059 and NAS 1638 Classes
56
Iso 4406:1999
56
15.1.1 ISO 4406 Table
56
15.1.2 Overview of the Differences between ISO 4406:1987 and ISO 4406:1999
57
Sae as 4059
58
15.2.1 SAE as 4059 Table
58
15.2.2 Cleanliness Classes According to SAE
58
Absolute Particle Count Larger than a Defined Particle Size
58
Specifying a Cleanliness Class for each Particle Size
59
Specifying the Highest Cleanliness Class Measured
59
Nas 1638
59
16 Service
60
Shipping Address for Recalibration and Repair Work
60
Calibrating the FCU
60
17 EC Declaration of Conformity
61
Advertisement
HYDAC International FCU 1000 Series Operating And Maintenance Instructions Manual (35 pages)
Fluid Control Unit
Brand:
HYDAC International
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Table of Contents
3
Foreword
5
Customer Service
6
Modifications to the Product
6
Warranty
6
1 General Safety Precautions
8
Obligations and Liability
8
Explanation of Symbols and Warnings, Etc
8
Basic Symbols
8
Proper/Designated Use
9
Improper Use
9
Safety Devices
9
Informal Safety Precautions
9
Instructions to be Followed in the Event of an Emergency
10
Safety Measures to be Followed in Normal Operation
10
Electrical Hazards
10
Maintenance, Servicing and Troubleshooting
10
Modifications to the FCU
11
Cleaning the FCU and Disposal of the Media and Agents Used
11
2 Transportation, Packing, Storage
12
Transportation & Packing
12
Storage
12
Storage Conditions
12
3 Model Code / Product Identification
12
4 Scope of Delivery
13
5 Description of the FCU
14
Product Description
14
Performance Features
14
Functional Description
15
Restrictions Pertaining to the Use of the FCU
16
Operation Elements
17
Display Rotatable/Adjustable as Needed
17
Dimensions
18
Hydraulic Diagram
18
6 Installation & Commissioning
19
Unpacking
19
Hydraulic Installation
19
General Selection Guidelines for Measurement Points
19
Performing Measurements on Pressurized Test Points
20
Performing Measurements on Sample Bottles
22
Electrical Installation
23
Commissioning
23
7 Description of the Measuring Modes
24
Mode M1: Measure Continuously
24
Modes M2, M3, M4, M5 - Not Applicable for FCU1000
24
8 Operation
24
Display and Keypad Elements
24
Modes and Menus
25
Power up Menu
25
Measuring Menu
27
9 Status LED / Error Codes
28
10 Factory Default Settings / Basic Settings
29
Power up Menu
29
Measuring Menu
29
11 Removing the FCU from the Hydraulic System
29
12 Maintenance
29
Cleaning the Suction Strainer
30
Disposal / Recycling and Decommissioning
30
13 Spare Parts
31
14 Accessories
31
15 Technical Data
31
16 ISO 4406 and SAE as 4059 Classes
33
Iso 4406:1999
33
ISO 4406 Table
33
Sae as 4059
34
SAE as 4059 Table
34
17 Explanation of Terms Used in Measurement Systems
35
18 Recalibration / Service
35
Shipping Address for Recalibration and Repair Work
35
Advertisement
Related Products
HYDAC International FCU 2110-5
HYDAC International FCU 2210-5
HYDAC International FCU 1210-4-U
HYDAC International FCU8111/-Aviation
HYDAC International FCU2000-1 Series
HYDAC International FCU8000 Series
HYDAC International FCU2000-5 Series
HYDAC International FCU2000-4 Series
HYDAC International FMMP
HYDAC International FPU-1
HYDAC International Categories
Water Filtration Systems
Control Unit
Industrial Equipment
Measuring Instruments
Accessories
More HYDAC International Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual