Dry Run Drain Pump - HYDAC International FluidAqua Mobil FAM 15-P Operating And Maintenance Instructions Manual

Table of Contents

Advertisement

FluidAqua Mobil - FAM 10/15-P

Dry run drain pump

Description
Malfunction:
"Wrong motor rotation"
1.
Switch off FAM, pull out mains plug
2
Replacement of two phases on the mains plug, check mains voltage
3.
Plug mains plug back in, switch on main switch
4.
Check direction of rotation in accordance with the direction of rotation
arrow on the pumps
->a. The fault recurs
5.
->b. The failure does not recur
6.
Pull out mains plug, check mains cable and plug, replacing as necessary
7.
The failure is repaired.
Direction of rotation, electric motor
The unit will be damaged
► After replacing electric motors, check the direction of rotation in manual
operation before commissioning.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
-> proceed to Step 6.
-> proceed to Step 7.
NOTICE
en(us)
Troubleshooting
Page 50 / 80
2011-01-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fluidaqua mobil fam 10

Table of Contents