Electrical Fuses - HYDAC International FluidAqua Mobil FAM 15-P Operating And Maintenance Instructions Manual

Table of Contents

Advertisement

FluidAqua Mobil - FAM 10/15-P
Error message
Heater fault (only with
option heater)
No parameter block

Electrical fuses

Automatic safety devices have been installed into the control cabinet for the security
of the operating voltage transformer.
Fuse
F1
F2
F3
F4
F5
F6
F7
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
Cause
was selected without
connecting the Sub D plug
of the FCU.
Oil too hot due to
interruption of oil flow or
faulty thermostat.
Setup settings of the
TD200 deleted.
The primary side of the transformer has 2A 400V
The primary side of the transformer has 2A 400V
The secondary side of the transformer has 3A 250V
The secondary side of the transformer (control current circuit)
has 1A 250V
The secondary side of the transformer (control current circuit)
has 1A 250V
Contamination Sensor Display CSD (Optional)
Contamination Sensor CS (Optional)
en(us)
Troubleshooting
Remedy (also see
following detailed
description)
operating mode.
Reset the safety
thermometer. Remove the
cover of the heater to do
so. Clean the suction
screen, possibly shortening
the length of the suction
hose.
Reenter setup values.
(Please contact our
Technical Sales Office. For
contact information, see the
chapter "Foreword")