FluidAqua Mobil - FAM 10/15-P

E/V/R pump motor protection

1.
2
->a. The fault recurs
3.
->b. The failure does not recur
4.
5.
->a. The fault recurs
6.
->b. The failure does not recur
7.
8.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
Description
Malfunction:
"E/F/V pump motor protection"
Switch off FAM at the main switch and pull out mains plug
Open the switch cabinet door, switch the motor protection switch
and/or fuse back on "I" that has tripped and check the setting of the
motor protection switch and/or the voltage capacity of the fuse in
accordance with the motor type plate and/or the heater type plate.
Measure the current consumption of the engines whose motor
protection switch
or fuse has tripped.
Close switch cabinet door, main switch to "On", start FAM
Check the operating viscosity of the medium (only for motor protection
switch),
perform maintenance work on the vacuum pump
The failure is repaired.
-> proceed to Step 4.
-> proceed to Step 8.
-> proceed to Step 7.
-> proceed to Step 9.
en(us)
Troubleshooting