FluidAqua Mobil - FAM 10/15-P

Inlet (IN) clogged

1.
2.
3.
4.
5.
->a. Yes
6.
->b. No
7.
8.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
Description
Malfunction:
"Inlet clogged"
Cause: Medium cannot make its way into the vacuum chamber
Check locking features in the suction line. Open if blocked.
Check suction strainer and clean if necessary
To reset the failure, press the RESET key
Malfunction reappears after ~ 4 minutes?
Check the following points:
Check the suction pipe for cross-section constriction
-
Check the functioning of vacuum pump in manual mode
-
Check the position of the shut-off device in the suction line
-
The failure is repaired.
-> proceed to Step 7.
-> proceed to Step 8.