FluidAqua Mobil - FAM 10/15-P

Dry running E-pump

1.
2.
3.
4.
5.
6.
7.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
Description
Fault "Dry running, E-pump"
Cause: Insufficient inflow into vacuum chamber
The suction-side pressure loss is too great. Possible remedies:
Cleaning the suction strainer
-
Reduce the suction height
-
Reduce the absolute pressure in the vacuum chamber
-
e.g. from 500 mbar
Increase fluid temperature
-
Enlarge the diameter of the suction hose
-
Shorten the length of the suction hose
-
Check the 2/2-directional solenoid valve at the inlet
-
Suction port in the tank sucks in air:
Position the suction port lower
-
Tank to be cleaned is too small
-
Check the functioning of vacuum pump in manual mode
Find and remedy corresponding cause
To reset the failure, press the RESET key
The failure is repaired.
-> 400 mbar
(abs)
(abs)
en(us)
Troubleshooting
Page 51 / 80