Starting Up The Fam; Switching On The Fam - HYDAC International FluidAqua Mobil FAM 15-P Operating And Maintenance Instructions Manual

Table of Contents

Advertisement

FluidAqua Mobil - FAM 10/15-P

Starting up the FAM

Connection IN / OUT closed
The unit will be destroyed
► Check to be sure that all of the locking fixtures at the inlet / outlet are in
"open" position each time before start-up.

Switching on the FAM

Move main switch to the "ON" position and wait until the "Fault" lamp lights up briefly
(lamp test) and this message: appears on the display.
Press the
1. Vacuum pump starts,
2. Inlet valve opens and the vacuum chamber is filled.
3. When the vacuum chamber is filled to filling level 02, the evacuation pump is
started up and the starting period is finished.
4. Automatic mode is active:
Now regulate the vacuum pressure with the throttle valve on the right of the vacuum
gauge, depending on the operating viscosity.
Operating viscosity
2
50 mm
/s hydraulic oil
2
300 mm
/s lubrication oil
2
50 mm
/s ester oil
Some oils begin to foam intensively when they enter the vacuum chamber. This can
especially be the case when the water content is very high, but also when the oil is
old or high viscosity media are used. If too much foam is caused, it is drawn in by
the vacuum pump.
In this case, for example, reduce the vacuum from 300mbar to 400mbar.
HYDAC FILTER SYSTEMS GMBH
BEWA FAM10-15-P 3193324b en-us 2011-01-19.doc
NOTICE
Ready for operation
--> Press start
key. Now the system starts with the starting phase.
FluidAqua operating
Starting
FluidAqua operating
Automatic mode
Pressure setting (absolute pressure)
300 mbar / 30 kPa
400 mbar / 40 kPa
400 mbar / 40 kPa
en(us)
Starting up the FAM
Page 37 / 80
2011-01-19