Out-of-Band Management Interface Configuration

1. Log onto the switch using the serial console port or management port on the
NE10032 front panel.
2. Enter the management interface configuration mode:
3. Configure an IP address and subnet mask:
4. Configure the out-of-band default gateway:

In-Band Management Interface Configuration

1. Log onto the switch using the serial console port or management port on the
NE10032 front panel.
2. Enter the SVI interface configuration mode:
3. Configure the in-band management IP address:
4. Configure the in-band default gateway:
© Copyright Lenovo 2019
Complete the following steps to configure an out-of-band management IP address
and a default gateway:
NE10032> enable
NE10032# configure [terminal]
NE10032(config)# interface mgmt 0
NE10032(config-if)#
NE10032(config-if)# ip address 10.254.87.6/24
NE10032(config-if)# exit
NE10032(config)#
NE10032(config)# vrf context management
NE10032(config-vrf)# ip route 0.0.0.0/0 205.21.17.1
NE10032(config-vrf)# exit
NE10032(config)#
Complete the following steps to configure an in-band management IP address over
an SVI interface and an associated default gateway:
NE10032> enable
NE10032# configure [terminal]
NE10032(config)#
NE10032(config)# interface vlan 1
NE10032(config-if)# ip address 10.254.87.6/24
NE10032(config-if)# exit
NE10032(config)#
NE10032(config)# ip route 0.0.0.0/0 205.21.17.1
Chapter 5: Initializing the NE10032
83