Troubleshooting - Extron electronics Inline CIA116-1 Operation Manual

Computer interface with modular a/v faceplate table / rack mount
Table of Contents

Advertisement

im Vertrieb von
Required Accessories (Ordered Separately)
Input and Local Monitor Adapter and Extension Cables:
VGA: IN8000 Series 15-pin HD male to 15-pin HD female, various lengths from 3' to 100'
For Other Computers: Refer to the table on page 5
Optional Accessories
Audio Input Cables:
IN9106: 3.5mm stereo mini male to 3.5mm stereo mini male, 6' long
IN9107: (1) 3.5mm stereo mini male to (2) RCA male, 6' long
Installation Hardware:
IN9253: Flush-mount brackets - For Mounting CIA116 through Hole in Table Top
IN9254: Rack Ears - Rack Mounts Unit in 1 U Rack Space, Rack Ear Holds Up to
4 Additional Single-Space A/V Connector Modules
IN9255: Rack Ears - Rack Mounts Unit in 1 U Rack Space
Coaxial Cables
Standard Resolution
Standard Resolution, Plenum
Super High Resolution
Super High Resolution, Plenum
Ultra High Resolution
All cable grades are available in lengths from 3' to 250' pre-terminated with high quality BNC connectors or as bulk cable.

Troubleshooting

Problem: The display device connected to the CIA116 output has a bad / scrambled image.
Œ
Solution 1: Verify that the correct input cable is being used (see the table on page 5).
Œ
Solution 2: The display device connected to the output of the interface may not be
compatible with the computer output. PC, MAC, SUN and other high-resolution
workstations have new and ultra high-resolution modes such as 1600 x 1200 and
1800 x 1440, and can output a video signal with a horizontal scan rate of over 100 KHz!
Many data monitors and data projectors are not compatible with these resolutions and
frequencies.
Œ
Solution 3: Check the dipswitch settings to make sure the unit is putting out a sync
format that the display device can use. For most applications, the default dipswitch
settings will work best (see page 9). For LCD / DMD / D-ILA / Plasma Display devices,
you may have to disable the horizontal position control.
Œ
Solution 4: The RGBS or RGBHV cable may have a bad sync line. Try running the sync
through another cable.
©2001 - INLINE, Inc.
www.camboard.de
CAMBOARD Electronics
RGB Installation Cables
3-Conductor
4-Conductor
IN7300-3
IN7200-3
Tel. 07131 911201
Fax 07131 911203
5-Conductor
IN7000-4
IN7000-5
IN7000P-4
IN7000P-5
IN7300-4
IN7300-5
IN7400P-5
IN7200-5
IN7200-6
CIA116 Operation Manual - V1.3 01/03/01
ce-info@camboard.de
11

Advertisement

Table of Contents
loading

Table of Contents