EAGLEHAWK NX CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS

SYSTEM OVERVIEW

Overview of Hardware

feature
description
NTC10kΩ / NTC20kΩ / 0...10 V / slow BI, 0.4 Hz
UI
NTC10kΩ / NTC20kΩ / 0...10 V fix pull-up / slow BI, 0.4 Hz
open = 24 V / closed 2.0 mA / totalizer 15 Hz
BI
AO
0..11 V (max. 1 mA)
Relay N.O. contact: 3 A, 250 VAC, 30 VDC
Relay N.O. contact (high in-rush): 10 A, 250 VAC, 30 VDC
BO
Relay N.O. contact with one common: 3 A, 250 VAC,
30 VDC
total I/Os
bus
RS485-1, isolated, BACnet MS/TP, Panel Bus, or Modbus
interfaces
RTU Master or Slave communication
RS485-2, non-isolated, BACnet MS/TP, Panel Bus, or
Modbus RTU Master or Slave communication (NOTE: It is
imperative that the RS485-2 be powered by a power supply
having the proper polarity. Failure to do so will make data
transmission impossible.)
Ethernet Interfaces
access, BACnet IP communication, Niagara Network,
Modbus TCP)
USB 2.0 Device Interface (as Network Interface)
USB 2.0 Host Interface (max. 200 mA)
RS232 M-Bus communication via 15-meter-long PW3 /
PW20 / PW60 converters
power LED (green)
status LED (red; indicates an active alarm; is controlled by
Niagara Alarm System; is configurable)
LED L1 (yellow; lit = Daemon starting; flashing = station
LEDs
starting; if L2 is also flashing, then the station has started)
LED L2 (yellow; lit = platform has started / is reachable;
flashing = station has started / is reachable)
bus status LEDs (for isolated RS485-1 interface)
1)
Depending upon bit rate. However, in the case of configuration of RS485-2 for Panel Bus, the communication rate is set to
115.2 kbps, and the max. cable length is hence 800 m.
2)
In the case of these devices, for Panel Bus functionality, an additional license must be purchased (see Table 19).
EN1Z-1039GE51 R1218
Table 3. Overview of models (hardware)
(
e-mail communication, browser
without HMI
max.
cable
length
400 m
0
0
4
4
400 m
0
0
0
0
400 m
0
0
4
4
400 m
0
0
2
2
400 m
0
0
3
3
400 m
0
0
1
1
400 m
0
0
0
0
--
0
0
14
14
1)
1200 m
1
2)
1
1
2)
1
1)
1200 m
1
2)
1
1
2)
1
100 m
2
2
2
2
3 m
1
1
1
1
3 m
1
1
1
1
1)
1000 m
1
1
1
1
--
1
1
1
1
--
1
1
1
1
--
1
1
1
1
--
1
1
1
1
--
2
2
2
2
4
order no.
with HMI
8
8
0
0
4
4
8
2
2
0
0
0
0
2
4
4
0
0
4
4
4
4
4
0
0
2
2
4
4
4
0
0
3
3
4
1
1
0
0
1
1
1
3
3
0
0
0
0
3
26
26
0
0
14
14
26
1
2)
1
1
2)
1
1
2)
1
1
1
2)
1
1
2)
1
1
2)
1
1
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
8
2
4
4
4
1
3
26
2)
1
2)
1
2
1
1
1
1
1
1
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents