Troubleshooting Intended use Customer service and guarantee Environmental protection and recycling Exploded view of the unit Spare parts list Electrical wiring diagram CLK 80-RV Electrical wiring diagram CLK 170-RV Commissioning fan oil burner 20-21 Maintenance protocol Technical data Carefully read this operating manual prior to commissioning / using the unit! This operating manual is a translation of the German original.
REMKO CLK 80/170-RV Safety notes Always observe the respective local building code and fire prevention guidelines as well as the guidelines of the accident prevention and insurance associations as a basic rule when using the unit. The units may only be operated...
REMKO Multiflex profile. oil pre-heating fitted as standard. With the CLK 80-RV this In simple ventilating mode the is available as an option unit can be used to recirculate the (EDP no. 1071411) .
REMKO CLK 80/170-RV installation instructions The safety regulations installation in closed, well Room heating ventilated areas without of the accident prevention and insurance associations, exhaust gas connection The units may only be operated ■ the respective regional building for room heating with a room...
Safety temperature limiter (STB) 1. Unscrew protective cap [1]. Only "REMKO original The unit is permanently switched replacement parts" must off by the safety temperature be used when replacing safety limiter (STB) in the event devices.
REMKO CLK 80/170-RV Exhaust ducting It is also possible to operate Fault-free operation All parts of the exhaust gas ■ ■ the units outside or in open is guaranteed if the exhaust routing must be reliably rooms / halls without exhaust gas gas routing is fitted in a rising fastened.
Before commissioning If the cycle intervals are too The units should be checked for Air distribution ■ short the length and layout visible defects on the operating The units are equipped with a high of the hot air routing should and safety devices as well performance radial fan, which be checked...
REMKO CLK 80/170-RV Commissioning Paraffin formation with low One person, who has been Control panel outside temperatures adequately trained in the handling of the unit, should be tasked with Even at low outside temperatures the operation and monitoring it is necessary to ensure that there of the unit.
Shutdown Heating with room thermostat Ventilate (Accessories) In this switch position the supply 1. Move the operating The units operate fully air fan runs permanently. switch to the "0" automatically and exclusively The units can be used for air (off) position. in accordance with the room recirculation or ventilation temperature.
REMKO CLK 80/170-RV Care and maintenance Regular care and observation Check the fan blades and Cleaning the heat exchanger ■ of some basic points will ensure combustion chamber with heat trouble-free operation and a long exchanger for contamination 1. Set the operating switch service life.
Page 13
[2]. by authorised specialists 3. Loosen the 2 lower fastening Burner CLK 80-RV: X = 20 mm screws on the burner flange [6]. Burner CLK 170-RV: X = 30 mm 4. Loosen the clamping screw [7] on the burner flange 6 1.
REMKO CLK 80/170-RV troubleshooting tensioning the V-belt 9. Move the operating switch AttEntiOn to the "II" (Ventilate) position. Before undertaking any work 1. Remove the two side air intake If the supply air fan now starts on the units, the power grills.
"certificate material, please consider our of their structural design and of guarantee" to REMKO gmbH & environment. equipment. Co. Kg at the time when the units Our units are carefully packed are purchased and commissioned.
REMKO Multiflex oil pre-heating, REMKO 2-strand oil filter, serial with CLK 170-RV with factory- Serial with CLK 80-RV with fitted oil burner. factory-fitted oil burner. We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
REMKO CLK 80/170-RV Commissioning the forced-air oil burner Preparatory tasks Adjusting the ignition electrode and baffle plate AttEntiOn The commissioning of the forced-air oil burner may only be carried out by trained specialists. After loosening the 4 fastening bolts the mounting baseplate M is pulled off the housing g.
Page 21
1. burner settings. 1. Remove the stopper on the measurement nozzle "P". CLK 80-RV Adjusting the air flap Turning to the left (–) 2. Fit a suitable oil pressure = smaller scale value Adjust the air flap as follows: manometer here.
CLK 80-RV CLK 170-RV Unit type nominal heating capacity Max. Nominal heat capacity Nominal flow rate 6,140 10,340 pressure (Max. total) Fuel Heating oil EL acc. to DIN 51603-1 or diesel fuel fuel consumption 15.5 Max. Danfoss oil nozzle 1.75 / 60°S...