Connection Terminals For Spring Contacts; Technical Data; Electrical Connections; External Connections - Bayrol PoolManager Series User Manual

For the measurement, control, and dosage system for swimming pools
Table of Contents

Advertisement

48
Hardware description
48.3

Connection terminals for spring contacts

48.3.1

Technical data

All connection terminals have so-called spring contacts.
Connection terminals are designed for the following conductor cross-
sections:
Cable type
fixed
Flexible
(no wire end ferrule)
Flexible
with wire end ferrule
48.3.1.1 Connect cable
Requisite user qualification:
ELECTRICAL SPECIALIST
Electrical connections may only be performed by an
ELECTRICAL SPECIALIST as defined in the chapter
User qualification.
Spring contacts can be opened with a simple screwdriver in order to
connect a cable:
1.
Insert a matching screwdriver into the aperture above the
terminal as far as possible.
2.
Gently pull up on the screwdriver's handle. This lever effect
pushes the screwdriver's tip down, thereby opening the spring
contact.
3.
Once the spring contact is open, insert the cable into the
terminal.
4.
Pull out the screwdriver.
5.
Check that the cable is sitting securely by pulling on it lightly.
IMPORTANT NOTICE!
Force application on connection terminals
To avoid damage, do not apply any excessive force on
the terminal using the screwdriver.
Conductor cross-section [mm²]
min.
max.
0.2
2.5
0.2
1.5
0.25
1.5
User Manual PoolManager
48.4

Electrical connections

48.4.1

External connections

1
Cable aperture for network cable
2
pH electrode
3
Redox (mV) electrode
4
Level monitoring pH (suction lance)
5
Level monitoring redox (mV) / Cl (suction lance)
6
Input IN 1 or flow monitor
7
BNC connection for free chlorine measurement (optional)
48.4.1.1 Cable fittings
8
11 small cable fittings
(for cable diameters 3 mm - 6.5 mm)
9
5 large cable fittings
(for cable diameters 5mm - 10mm)
All cables are inserted into the terminal box via cable fittings. Proceed
as follows:
1.
Loosen the nut on the cable fitting such that it is barely on the
thread. You can also take it off completely.
2.
Remove the seal plug.
3.
Insert the cable through the nut and
cable fitting and into the terminal box.
4.
Connect the cable..
5.
Tighten the nut (but not forcefully) in order to ensure a reliable
seal.
®