25

Filter pump control

24.4.1.3 Control of unit with
external voltage supply
For external systems with their own power supply (AC or DC), the
For external systems with their own power supply (AC or DC), the
power supply can be turned on and off via PoolManager
power supply can be turned on and off via PoolManager
output.
The following figure schematically shows an application example for
The following figure schematically shows an application example for
switch output OUT 1.
1
External system to be controlled
2
External system's voltage supply input
External system's voltage supply input
3
External system's voltage supply
(AC or DC)
4
External system's voltage supply output
External system's voltage supply output
24.4.2

Lifespan of relay switching contacts

Lifespan of relay switching contacts
Depending on application, the lifespan of a relay switching contact
Depending on application, the lifespan of a relay
may be limited.
In general, the lifespan of a relay contact is reduced by high circuit
In general, the lifespan of a relay contact is reduced by high circuit
currents.
The following guideline values can be used for orientation:
The following guideline values can be used for orientation:
230V~, 0.5A, resistive load
Lifespan > 1,000,000 switches
230V~, 4A, resistive load
Lifespan > 300,000 switches
25
Filter pump control
Filter pump control
25.1

Safety information

®
switch
25.2

Overview

PoolManager
filter pumps are simply turned on and off. Suitable variable filter pumps
filter pumps are simply turned on and off. Suitable
can additionally be set into three different operating modes:
can additionally be set into three different operating modes:
Normal operation
(Normal filter operation)
Reduced output
(Energy saving mode, e.g. for night reduction)
(Energy saving mode, e.g. for night reduction)
Increased output
(Increase pump output, e.g. for filter rinsing, connecting water
(Increase pump output, e.g. for filter rinsing,
attractions, or solar power operation)
attractions, or solar power operation)
PoolManager
options:
Multiple flexibly programmable timers
Multiple flexibly programmable timers
Free configurable blocking of dosage (pH and disinfection)
Free configurable blocking of dosage (pH and disinfection)
depending on the filter pump operating mode
Linking of each filter pump operating mode with an external switch
Linking of each filter pump operating mode with an external switch
or push button
Flexible allocation of up to three relay switch outputs for the filter
Flexible allocation of up to three relay switch outputs for the filter
pump's various operating modes
pump's various operating modes
Operation of relay switch outputs optionally as potenti
Operation of relay switch outputs optionally as potential free
switch or as 230V~-output
Alternative filter pump triggering via a power output 0/4-20mA
Alternative filter pump triggering via a power output 0/4
(optional)
25.3

Menu Filter pump

The configuration menu for filter pump control is called up with the
The configuration menu for filter pump control is called up with the
following icon:
Filter pump
User Manual PoolManager
®
Requisite user qualification:
Requisite user qualification:
TRAINED SPECIALIST or
TRAINED SPECIALIST or
ELECTRICAL SPECIALIST
ELECTRICAL SPECIALIST
Connection, configuration, and start
Connection, configuration, and start-up of filter pump
control may only be performed by a TRAINED
control may only be performed by a TRAINED
SPECIALIST or an ELECTRICAL SPECIALIST as
ALIST or an ELECTRICAL SPECIALIST as
defined in the chapter User qualification.
defined in the chapter
HAZARD!
Hazard from turning on filter pump
Hazard from turning on filter pump
Turning on a filter pump can yield hazards for
Turning on a filter pump can yield hazards for
swimming
swimming
(e.g. due to current or suction effects).
(e.g. due to current or suction effects).
Potential consequence:
Potential consequence: Death or the gravest
degree of injury, heavy material damage.
degree of injury, heavy material damage.
• Turning on a filter pump is expressly PROHIBITED
Turning on a filter pump is expressly PROHIBITED
for all applications in which the safety of persons,
for all applications in which the safety of persons,
animals, and property is not completely guaranteed
animals, and property is not completely guaranteed
at all times and under all circumstances.
at all times and under all circumstances.
• Safety is exclusively in the system operator's
Safety is exclusively in the system operator's
sphere of responsibility.
sphere of responsibility.
• The device manufacturer disclaims all liability.
The device manufacturer disclaims all liability.
®
offers a triggering option for filter pumps. Conventional
offers a triggering option for filter pumps. Conventional
®
filter pump control additionally offers the following
filter pump control additionally offers the following
p operating mode
guests
guests