Information Displayed; Event Display; Example, O2 (Bayrosoft) Dosage; Device Settings - Bayrol PoolManager Series User Manual

For the measurement, control, and dosage system for swimming pools
Table of Contents

Advertisement

19

Device settings

18.2

Information displayed

For each event, the following supplemental information is stored and
For each event, the following supplemental information is stored and
displayed in the event log:
Date and time
User
(Provided a user can be allocated to the event, e.g. parameter
(Provided a user can be allocated to the event, e.g. parameter
changes, calibrations, manual dosing, etc.)
changes, calibrations, manual dosing, etc.)
Type of access
Local device operation (local)
Remote access from the local network (
Remote access from the local network (LAN)
Remote access from the Internet (Web)
18.2.1

Event display

Here is a detailed explanation of how an event is displayed using the
Here is a detailed explanation of how an event is displayed using the
example of a parameter change:
1
Symbol (depending on type of event)
2
Serial number
3
Date
4
Time
5
User name and access level, e.g. Service (Level 3)
6
Type of access
(local / LAN / Web)
7
Designation of changed parameter
8
Old parameter value (prior to change)
9
New parameter value
18.2.2

Example, O2 (BayroSoft) dosage

(BayroSoft) dosage
This example of O2 (BayroSoft) dosing is intended to illuminate what
This example of O2 (BayroSoft) dosing is intended to illuminate what
the event log makes possible:
1 06.06.2012
08:44
Main dos.O2 ended (2.4/2.4l)
Main dos.O2 ended (2.4/2.4l)
2 06.06.2012
08:30
Main dos.O2 continued(1.0/2.4l)
Main dos.O2 continued(1.0/2.4l)
3 06.06.2012
08:30
(Level alarm) end
4 06.06.2012
08:10
Main dos.O2 blocked (level)
Main dos.O2 blocked (level)
5 06.06.2012
00:10
Level alarm O2
6 06.06.2012
00:00
Main dos.O2 started (2.4l)
Main dos.O2 started (2.4l)
This series in the event log is caused by the following events
This series in the event log is caused by the following events
At midnight, PoolManager
®
amount of 2.4 litres.
After 10 minutes, however, the BayroSoft canister is empty. That
After 10 minutes, however, the BayroSoft canister is empty. That
triggers a level alarm, which blocks O2 main dosage.
triggers a level alarm, which blocks O2 main dosage.
On the next morning at 8:30 a.m., the empty BayroSoft canister is
On the next morning at 8:30 a.m., the empty BayroSoft canister is
replaced.
Web)
Service (Level 3)
starts O2 main dosing with a dosing
starts O2 main dosing with a dosing
User Manual PoolManager
The level alarm ends, and O2 main dosage is continued, although
e level alarm ends, and O2 main dosage is continued, although
there was already 1.0 litre of BayroSoft dosed prior to the level
there was already 1.0 litre of BayroSoft dosed prior to the level
alarm. Thus, another 1.4 litres need to be dosed.
alarm. Thus, another 1.4 litres need to be dosed.
At 8:44 a.m., the O2 main dosing ends regularly after the dosing
At 8:44 a.m., the O2 main dosing ends regularly after the dosing
amount of 2.4 litres is fully met.
litres is fully met.
19
Device settings
The menu Device Settings is called up as follows:
is called up as follows:
Menu hotkey
Device Settings
The menu provides the following setting options:
The menu provides the following setting options:
Menu Device settings
Menu Language
Configuration of the desired menu language
Configuration of the desired menu language
Menu Style
See section individualisation
See section
Icon Style
Background image
Controller name
Entry of the name for the PoolManager
Entry of the name for the PoolManager
name is shown in the browser during remote access
name is shown in the browser during remote access
and makes it possible to distinguish among multiple
and makes it possible to distinguish among multiple
devices.
Date & time
Set date and time, and configuration of associated
Set date and time, and configuration of associated
options
Energy saving mode
Settings for energy saving mode
Settings for energy saving mode
19.1
Date & time
The following functions are available in the menu Date & time:
The following functions are available in the menu Date & time:
Menu Date & time
Time
Display and configuration of current
Display and configuration of current time
Date
Display and configuration of current date
Display and configuration of current date
Day of week
Display of current weekday.
Display of current weekday.
The weekday is automatically set correctly upon
The weekday is automatically set correctly upon
setting the date.
setting the date.
Summer / winter time
Configuration of the change between summer and
Configuration of the change between summer and
auto / manual
winter time.
Auto
Manual
user
Standard setting (default): Auto
Standard setting (default): Auto
Time +1h
The current time is moved forward by one hour
The current time is moved forward by one hour
Time -1h
The current time is moved back by one hour
The current time is moved back by one hour
®
PoolManager
automatically sets time as follows in automatic
configuration:
On the last Sunday in March, time is moved forward
On the last Sunday in March, time is moved forward
from 2:00 a.m. to 3:00 a.m.
On the last Sunday in October, time is moved back
On the last Sunday in October, time is moved back
from 03:00 a.m. to 02:00 a.m.
from 03:00 a.m. to 02:00 a.m.
Once the automatic change has been made, the unit will show a
Once the automatic change has been made, the
notification with the newly configured time. It can then be checked and
notification with the newly configured time. It can then be checked and
corrected manually as needed.
®
®
unit. This
The change is made automatically
The change is made manually by the
sets time as follows in automatic
48