Universal switch outputs (4x)
The following settings are possible for each of the 6 time intervals:
Sub-menu Programable timer (1..6)
Days of week
Selection of one or multiple weekdays on which the
time interval should be active.
If no weekday is activated, then the entire time
interval is inactive.
Switch-on time
Time at which switch-on occurs.
Switch-off time
Time at which switch-off occurs
Interval mode
Activation of interval operation
(Periodic switching on and off)
Switch-on interval
Switch-on duration for interval operation.
Switch-off interval
Switch-off duration for interval operation.
24.3.2

Basic configuration

The menu Basic configuration is used to configure the basic settings
for a switch output. This is generally done once upon placing a switch
output into operation.
The following settings are available:
Sub-menu Basic configuration
Relay output
Relay switch output used for the universal switch
output.
Block in the event of
Yes
Output is turned off if flow signal is missing.
missing flow
Blocking by filter
Yes
The output is turned off if the filter pump is in
pump operating mode
the corresponding operating mode.
Prerequisite: PoolManager
Blocking via input.
Yes
The output is turned off if the selected input is
in the state indicated.
Blocking by another
Yes
The output is turned off if the other output
output
selected is in the state indicated.
External switch or
See External switch or push button.
push buttons
For each relay switch output, the following settings are available:
Setting
Description
None
The universal witch output is not used.
OUT 1 [26]
Relay switch output OUT 1 [terminal block 26]
OUT 2 [27]
Relay switch output OUT 2 [terminal block 27]
OUT 3 [30]
Relay switch output OUT 3 [terminal block 30]
OUT 4 [31]
Relay switch output OUT 4 [terminal block 31]
pH+ [22]
Dosage relay pH + [terminal block 22]
Can only be used
if no pH+ dosage is used.
pH- [21]
Dosage relay pH + [terminal block 21]
Can only be used
if no pH- dosage is used.
INFO
Terminal block indication
For the relay outputs OUT1 ... OUT4, the terminal block
number is indicated directly in the menu. This is the
number in brackets, e.g. [26] for OUT1.
®
controls the filter pump.
User Manual PoolManager
INFO
Toggle switch OUT4
The relay output OUT4 is designed as a toggle switch.
When active (on), terminal block [31] is turned on.
When inactive (off), terminal block [32] is turned on.
All other switch outputs are designed as simple on/off
switches.
24.3.2.1 External switch or push buttons
Each switch output can be linked with an external switch or device,
which facilitates turning the function on or off manually.
The following settings can be configured:
Sub-menu External switch or device
External switch input
Selection of an input to which the external switch is
connected
(IN 1 [6] / IN 2 [7] / IN 3 [8] / IN 4 [9] / none)
Type of external
On/off switch or push button.
switch
For on/off switch only
External switch
Defines the operating mode when external
switch is turned on:
• Output ON
• Output AUTO,
(Operating mode controlled by PoolManager
External switch off
Defines the operating mode when external
switch is turned off:
• Output OFF
• Output AUTO,
(Operating mode controlled by PoolManager
For push buttons only
Function of external
Start timer or
push buttons
Output on/off
Timer for
Switch-on duration
external push button
(For the function Start timer)
24.3.3

Security settings

HAZARD!
Hazard via remote access
Depending on the installation, hazards may be yielded
by universal switch outputs, particularly via remote
access.
Potential consequence: Death or the gravest
degree of injury, heavy material damage.
• Release of remote access to universal switch
outputs is expressly PROHIBITED for all
applications in which the safety of persons,
animals, and property is not completely guaranteed
at all times and under all circumstances; especially
for remote access.
• Safety is exclusively in the system operator's
sphere of responsibility.
• The device manufacturer disclaims all liability.
®
®
)
®
)