Download Print this page

Troubleshooting - Makita DJR187 Technical Information

Cordless recipro saw
Hide thumbs Also See for DJR187:

Advertisement

8

Troubleshooting

Whenever you find any trouble in your machine, first, refer to this list to check the machine for solution.
8-1
Note in Repairing
(1) Use the full charged battery which has the star mark.
(2) When Housing is disassembled, check the conditions of the electrical parts (Connectors, Lead wires, Switches, etc.), Rotor,
Stator, Gear section, etc.
(3) Do the running test 10 times in every work mode.
8-2
Test for recognizing the short-circuit of FET (Field Effect Transistor) on controller
Trouble on Controller can be checked with Tester as follows.
Fig. 8-2-1
[1] Set Digital tester (1R402) in the Diode mode.
[3] Contact Black probe (a) with (+) Terminal (b).
Contact Red probe (c) with (-) Terminal (d).
Wait until the figure on Tester gets stable.
Note: Be careful not to reverse them. The reversed contacts could spoil the test.
[4] Controller is in order if Tester indicates 0.7V ~ 0.9V. If Tester indicates 0 V~0.4 V approx., Controller is broken. Replace it
with a new one.
[2] Remove the battery, and pull Switch trigger and hold it
at "ON position" with tape or the like.
Fig. 8-2-2
(d)
(c)
(b)
23 / 24
Fig. 8-2-2
(a)

Hide quick links:

Advertisement

loading