After the SIM refill it is necessary to send a command SMS to the ZEUS4 and reset the
counter.
;SCV=XXX;
Where XXX are number of days. For example in Slovenia SCV are 90 and in Italy 360 days.
NOTE: The parameter SCV must be sent by SMS command and should not be programmed
directly on SIM card!
MNF - When it is necessary to fix the GSM network to one provider we can use the MNF
parameter. The MNF parameter switches automatic network searching to manual.
For example:
MCC/MNC code for Simobil is 29340, Mobitel is 29341, TIM is 22201, and Vodafone Italy
is 22210;
More information about national MCC/MNC codes can be acquired at:
http://www.activexperts.com/activsms/networkcodes/
RAN – Number of rings before ZEUS4-VD answers. With this command you can set the
ring counter and unit automatically answers after programmed number of rings with this
parameter. The default value is 5 rings.
TST – A test SMS is sent periodically. ZEUS4-VD can send the test message in the interval
ranging from 1hour up to 240 hours.
Example: if the TST value is set to 12, the numbers linked to "LN7" receive a test message
every 12 hours.
ALC – ALC parameter, if adjusted to 1, enables that log is automatically cleared after it
becomes full.
LOGN – LOGN parameter defines the number of event log messages sent by SMS when
;PLOG; command is sent to the device
RNT – RNT parameter defines how long (in seconds) the device is dialing telephone
number before switching to another.
LOT – LOT parameter defines how long (in seconds) the device is connected to dialed unit.
ARST – ARST parameter defines periodic auto restart time (in hours) of the device.
CID – CID parameter enables Contact ID communication between the device and Central
Monitoring Station
LED – LED parameter enables you to turn LED lights on or off (default is 1 – enabled).
LNG – This command switches between the preprogrammed languages:
Example:
0=English, 1=Italian, 2=Slovenian, 3=Croatian, 4=Dutch
The default language is English.