LED INDICATION ..............................7 CONNECTION DIAGRAM ..........................8 ZEUS4 UNIT MANAGEMENT .......................... 10 ZEUS4 FUNCTIONS WITH PROGRAMMING INSTRUCTIONS ............... 11 WEB SERVER - LOG IN ..............................11 WEB SERVER – ADDING UNITS TO USER PROFILE ....................12 WEB SERVER-UNIT MANAGEMENT .......................... 14 CALLER ID ACCESS ...............................
Page 3
Figure 4: WEB Server-Sign In page ....................11 Figure 5: WEB Server-Main page select ADD mode ................ 12 Figure 6: WEB Server-Main page adding ZEUS4 units ..............12 Figure 7: WEB Server-Unit management window ................14 Figure 8: WEB Server-Caller ID Access ................... 15 Figure 9: WEB Server-Output setting ....................
ZEUS4 USER MANUAL FOR YOUR SAFETY SWITCH ON SAFELY Do not switch the unit on when use of wireless phone is prohibited or when it may cause interference or danger. INTERFERENCE All wireless phones and units may be susceptible to interference, which could affect performance.
USER MANUAL INTRODUCTION ZEUS4 family of devices are a simple GSM alarm gateway system designed to ensure low-cost, simple to install/use, reliable and single box solution for alarm gateway application. It is designed for unlimited range, wire free alarm application.
ZEUS4 USER MANUAL ZEUS4-VD FEATURES AND APPLICATIONS Features: Built-in GSM (LTE) module Up-to 10 Alarm notification numbers Caller ID numbers control (up-to 10 caller ID numbers) Build in IP alarm reporting 4 x Alarm Inputs ...
IMPORTANT removed!! Insert SIM card in ZEUS4 unit. Connect power cable to ZEUS4 unit (YOU MUST POWER THE ZEUS4 UNIT WITH THE POWER SUPPLY INCLUDED). Do not power with any other power supply. Power up the unit.
ZEUS4 USER MANUAL LED INDICATION Blue LED (LED1) – Indicates the level of the GSM signal from 1 to 5 LED flashes (1 is weak signal, 5 is excellent signal) Red LED (LED2) When LED 2 is ON the unit has a problem with a GSM network connection or the GSM part of the unit is out of order.
ZEUS4 USER MANUAL CONNECTION DIAGRAM Before connection the ZEUS4 please take a look at connection diagram for particular module. Figure 1: ZEUS4: ZEUS4-VD Connection diagram Page 8...
ZEUS4 USER MANUAL Figure 2: ZEUS4: ZEUS4-MC Connection diagram Figure 3: ZEUS4: ZEUS4-MC LITE Connection diagram DO NOT USE Power out (12V AUX) for electric lock driving! IMPORTANT Use separate power source for door electric lock! Page 9...
ZEUS4 USER MANUAL ZEUS4 UNIT MANAGEMENT Unit supports different types of management (programming): Unit can be programmed remotely by using WEB server access Unit can be programmed remotely by using Smartphone apps (Android and IOS). Unit can be programmed remotely by SMS commands (Optional).
ZEUS4 FUNCTIONS WITH PROGRAMMING INSTRUCTIONS As mentioned in previous chapters ZEUS4 unit can be programmed in various ways, this document will focus on most common programming way: WEB programming. SIM card in the ZEUS4 unit MUST have DATA PLAN to be able to use...
After login the user will be diverted to WEB server main window. This page is used to add/remove/search for ZEUS4 units from the user’s profile. Select “+” sign to select ADD ZEUS4 units to user’s profile. Figure 5: WEB Server-Main page select ADD mode...
Page 14
The IMEI is located on the cellular chip and also should be on the card board box of the ZEUS4. • Phone Number: The telephone number of the SIM card in the ZEUS4 unit - mandatory data. • SIM provider: Information needed to enable data connection between the server and the unit.
ZEUS4 USER MANUAL 8.3 WEB SERVER-UNIT MANAGEMENT After the ZEUS4 unit is added to user database, the user can change the configuration of the specific unit. All changes made by the user are listed in the Change Log window. By clicking Send to device button ALL changes are sending to the unit.
Caller ID access is a very simple way to control relay output defined in Caller ID output setting. User will by calling in the ZEUS4 unit trigger defined output. Settings for this function are found in the Caller id # tab.
ZEUS4 USER MANUAL 8.5 OUTPUTS SETTINGS The behaviors on the outputs are defined in the Outputs tab. Figure 9: WEB Server-Output setting Output 1 - Settings for output 1: • Output mode: User can select between 3 options Disable-Output is disabled.
Page 18
CID error indication: When CID function is errored, output defined under this section gets activated. NOTE Do to limitation of the outputs use additional outputs settings with care. NOTE ZEUS4-VD LITE and ZEUS4-MC LITE has only 2 outputs. Page 17...
ZEUS4 USER MANUAL 8.6 INPUTS SETTINGS The behaviors on the inputs are defined in the Inputs tab. Figure 10: WEB Server-Input setting • Caller ID enabled by input: Defined input will be used as a precondition for Caller ID function.
Page 20
• Minimum pulse length to trigger input: Minimum time required to trigger ARM/DISARM input (in seconds). • Delay before sending alarm: Defined delay (in seconds) before the ARM/DISARM event is sending out. NOTE ZEUS4-VD LITE and ZEUS4-MC LITE has only 2 inputs. Page 19...
ZEUS4 USER MANUAL 8.7 ADMINISTRATION Administration tab allows user to enable advanced settings: notification of unauthorized access, periodic test messages, lock down of the unit… Figure 11: WEB Server-Notification numbers • Phone number, User name: Phone number and user name of the user that will be receiving notification messages.
Page 22
SMS. • Administration allowed to remote program by SMS: By selection this option the user can “Lock down” the ZEUS4 unit, preventing any unauthorized user to change any configuration on the unit. • Automatic call to administrator 1: To prevent SIM card provider to lock out the SIM card from the network, user can define a periodic call out to telephone number under position 1.
ZEUS4 USER MANUAL 8.8 MISCELLANEOUS This tab is split into 2 sections. Figure 12: WEB Server-Misc General settings can be found: • SMS text Language: define the language of the SMS information sending out. User can select appropriate language in drop-down menu.
ZEUS4 USER MANUAL 8.9 ALARM IP CONFIGURATION This tab is used to configure parameters for alarm DATA connection. Figure 13: WEB Server-Alarm IP configuration • Alarm reporting over IP: Enable/Disable alarm reporting over DATA connection (GPRS connection). • Alarm reporting protocol: Selection of alarm reporting protocol.
ZEUS4 USER MANUAL 8.10 GENERAL SETTINGS This tab is used to define different parameters for alarm reporting. Figure 14: WEB Server - ZEUS4-VD General configuration Figure 15: WEB Server - ZEUS4-MC General configuration General settings: • Line open time (off hook): Max allowed time (in seconds) allowed for voice connection time.
Page 26
Local area network: Local area number. • Outgoing prefix: Outgoing prefix. • Enable DTMF control: Enable/Disable of DTMF control. • GSM priority: Input used to enable GSM by NOTE ZEUS4-VD LITE and ZEUS4-MC LITE has only 2 inputs and 2 outputs Page 25...
Need help?