Scaled Outputs
The FC-5000 Flow Display has two scaled output channels for use in applications
requiring remote data collection and/or monitoring� The outputs are firmware
configurable, and can be tied to parameters such as rates or total volume�
Connector Pin
1
2
3
4
ANALOG OUTPUT CONFIGURATIONS ARE DESIGNED TO PROVIDE A SOURCING
OUTPUT SIGNAL. THE RECEIVING DEVICE MUST NOT PROVIDE POWER TO
THE LOOP.
Oelay Output Connectors
The FC-5000 Flow Display has either two Form C relay output terminals or one
Form C and one Form A terminal�
Two Form C
Connector Pin
1
2
3
One Form C and One Form A
Connector Pin
1
2
3
Connector Pin
1
2
3
April 2019
TB7 (FOEQ OUT) or (ANALOG OUT)
Function
Output 1 Signal
Output 2 Signal
Output Ground
Shield (Chassis GND)
Table 4: Scaled output channels
TB3 (OELAY 1) and TB4 (OELAY 2)
Function
Normally Open (N�O�)
Signal Common
Normally Closed (N�C�)
Table 5: Relay output connectors, relay option "C"
TB3 (OELAY 1) - Form C
Function
Normally Open (N�O�)
Signal Common
Normally Closed (N�C�)
Figure 8: Form C Relay Output Connector
TB4 (OELAY 2) - Form A
Function
Connection Point 1
Not Used (No Contact)
Connection Point 2
Figure 9: Form A Relay Output Connector
CTL-UM-02765-EN-01
Oeference Pin
32
33
34
35
Oeference Pin
Oelay 1
Oelay 2
13
16
14
17
15
18
Oeference Pin
Oelay 1
13
14
15
Oeference Pin
Oelay 2
16
17
18
Installing the Flow Display