Technical data / Scope of supply
Performance data: Heating output / COP
at B0/W35 operating point to EN14511
at B0/W45 operating point to EN14511
Heating capacity ı COP
at B0/W55 operating point to EN14511
at B7/W35 flows analogous to B0/W35
Cooling capacity at max. flow rate (B15/W25), units with passive cooling: Identifier K
Limits of use
Heating circuit return min. I Heating circuit flow max.
Heat source return
additional operating points
Sound
Sound pressure level at 1m distance from edge of unit
Sound power level to EN12102
Heat source
Flow rate: minimum I nominal analogous to B0/W35 I maximum
Max. free heat pump pressure ∆p (with cooling ∆pK) ***) ı Flow rate
Approved anti-freeze
Anti-freeze concentration: Minimum frost protection down to
max. allowable operating pressure
Heating circuit
Flow rate: minimum I nominal analogous to B0/W35 I maximum
Max. free heat pump pressure ∆p (with cooling ∆pK) ı Volume flow
Pressure losses, heat pump ∆p ı Volume flow
max. allowable operating pressure
General unit data
Total weight (with cooling)
Box weight (with cooling) ı Tower weight (with cooling)
Refrigerant type ı Refrigerant capacity
Domestic hot water tank
Net volume
Impressed current anode
Domestic hot water temperature, heating pump mode I Electric heating element
Mixed water quantity according to ErP: 2009/125/EC (at 40°C, draw-off of 10 l/min)
Standing loss according to ErP: 2009/125/EC (at 65°C)
Maximum pressure
Electrics
Voltage code ı all-pole heat pump fusing *)**)
Voltage code ı Control voltage fusing **)
Voltage code ı Electric heating element fusing **)
Voltage code ı all-pole fusing for connection via a joint supply cable*)**)
WP*): effect. Power input at B0/W35 to EN14511 I Current input I cosφ
WP*): Max. machine current I Max. power input within the limits of use
Starting current: direct ı with soft starter
Degree of protection
Electric heating element output
Circulation pump power consumption, heating circuit I heat source
Other unit information
Safety valve, heating circuit I Heat source
Expansion valve, heating circuit I Heat source
Overflow valve I Changeover valve, heating -Domestic hot water
Vibration isolators, heating circuit I Heat source
*) Only compressor, **) Follow local regulations, ***) Figures for 25% mono-ethylene glycol
26
Subject to change without notice | 83056700fUK – Translation of the original operating manual | ait-deutschland GmbH
Monoethylene glycol I Propylene glycol I Methanol I Ethanol
included in scope of supply: • yes — no
included in scope of supply: • yes — no
SWC 122(H)(K)3 – SWC 142(H)(K)3
SWC 122(H)(K)3
kW ı COP
12,18 ı 5,00
kW ı COP
11,24 ı 3,76
kW ı COP
10,63 ı 2,97
kW ı COP
14,55 ı 6,06
kW
°C
min. I max.
°C
...
dB(A)
dB(A)
l/h
1900 ı 2800 ı 4200
bar (bar) ı l/h
0,7 (0,6) ı 2800
• I • I • I •
°C
bar
l/h
1050 ı 2050 ı 2600
bar (bar) ı l/h
0,38 (0,31) ı 2050
bar ı l/h
— (—) ı —
bar
kg (kg)
185 (193)
kg (kg) ı kg (kg)
120 (128) ı 65 (65)
... ı kg
R410A ı 2,25
l
integrated: • yes — no
up to °C ı up to °C
— I —
l
W
bar
... ı A
3~PE/400V/50Hz ı C10
... ı A 1~N/PE/230V/50Hz ı B10
... ı A 3~N/PE/400V/50Hz ı B16
... ı A
— ı —
kW ı A ı ...
2,44 ı 4,70 ı 0,75
A ı kW
9,44 ı 4,80
A ı A
— ı 26,0
IP
kW
9 ı 6 ı 3
min. — max. W ı W
2 – 60 ı 2 – 180
— I —
— I —
integrated: • yes — no
integrated: • yes — no
813469a
SWC 142(H)(K)3
13,50 ı 5,08
12,29 ı 3,76
11,76 ı 2,94
16,07 ı 6,31
10,8
12,5
20 I 60
20 I 60
-5 – 25
-5 – 25
B0W65
B0W65
31
35
43
48
2100 ı 3150 ı 4750
0,76 (0,7) ı 3150
• I • I • I •
-13
-13
3
3
1150 ı 2300 ı 2900
0,50 (0,41) ı 2300
— (—) ı —
3
3
200 (212)
130 (130) ı 70 (82)
R410A ı 2,38
—
—
—
—
— I —
—
—
—
—
—
—
3~PE/400V/50Hz ı C10
1~N/PE/230V/50Hz ı B10
3~N/PE/400V/50Hz ı B16
— ı —
2,66 ı 4,84 ı 0,79
10,62 ı 5,60
— ı 27,0
20
20
9 ı 6 ı 3
5 – 87 ı 3 – 180
— I —
— I —
• I •
• I •
• I •
• I •