gako unguator EMP Quick Start Manual page 40

Table of Contents

Advertisement

gako unguator Jar
The jar connected to the gako unguator EMP is
1
not a gako unguator jar.
The gako unguator Jar Lid was screwed alsant
2
onto the jar and the stirrer cants on automatic
insertion.
At first time extraction the ointment leaks out in
3
a gush.
4
Liquid leaks out on the bottom of the jar.
5
The jar does not attach into the lift arm.
Hold the gako logo, on top of the jar, to the front. Load the stirring shaft directly from the front
into the lift arm. Push the mixing unit up and with a slight turn counterclockwise (about a
quarter turn) fix the mixing unit into the lift arm.
Error
tab.: Operation Errors / Jar
pic.: quick-lock Coupling
Troubleshooting
The jar has to be substituted for a gako unguator
jar.
Open the jar and screw the lid on correctly.
Diminish air before the first time extraction.
The bottom of the jar was not completely
covered with foundation all the way to the rim
of the jar bottom. Ensure to cover the sealing
lip of the bottom with foundation.
After using the jar in a water bath, water
accumulated in the cavity on the bottom side
of the jar. The water cannot penetrate into the
jar itself through the sealing lip, remove the
excess water with a paper towel.
The jar is not an original gako unguator Jar.
Always use an original gako unguator Jar.
Please observe the correct handling of the
quick-lock coupling (see description below)
chapter 5 - page 4