Error codes

The stirrer lock detached during the mixing
F1
process.
The locking attempt cannot lock the stirrer
F2
(after 5 tries no success), it might be blocked.
The set jar size does not match the used jar
F3
size (the used jar is bigger).
The stirrer blocks (The device tries to fix it
F4
itself).
Please contact customer service for any malfunctions cannot be remedied using this informa-
tion.

Operation Errors

gako unguator Stirrer
The stirrer used is not compatible with the gako
1
unguator EMP.
There are problems while coupling the stirrer
2
with the gako unguator EMP.
The gako unguator Stirrer does not penetrate
3
completely in the mixture, since the formula is to
pasty, firm, or in powder form.
Error
tab.: error codes
Error
tab.: Operation Errors / Stirrer
Troubleshooting
Restart the mixing process.
Check if the jar is screwed in straight or if the
stirrer is bend.
The gako unguator Stirrer is not straight in
the gako unguator jar. Straighten the stirrer.
The used jar size must match the set jar size.
The device needs to restart.
Troubleshooting
The stirrer used is not an original gako unguator
stirrer. The gako unguator EMP has only been
tested, centered and aligned with original gako
unguator stirrers. All stirrers delivered after the
year 1996 are compatible with the gako unguator
EMP.
The gako unguator Stirrer is bent or damaged!
Replace it with an intact stirrer!
The gako unguator Stirrer is not straight in the
gako unguator jar. Straighten the stirrer.
To ensure the complete mixing of the recipe, you
can for example, warm cold recipe substances
in room temperature or assist pasty mixtures by
hand. Further help is usually no longer necessary.