Environmental
phenomena
Temperatures
Humidity
Corrosive gases
Altitude
Service life
MTBF
Vibration
Shock
Enclosure
Weight
Degree of protection
22
Basic
Description
standard
EN 60068-2-1
Operating
EN 60068-2-2
Storage and
transport
EN 60068-2-30
Operating
Storage and
transport
IEC
Operating
60068-2-60
Operating
Operating
MIL-HDBK
217F
Telcordia
IEC 60068-2-6
Operational
(sine)
IEC
Operational,
60068-2-64
endurance test
(random)
IEC
Operational
60068-2-27
EN 60950-1
Aluminum
EN 60529
Enclosure
RedFox 5528 Series
Test levels
-40 to +74°C (-40 to +165°F)
-50 to +85°C (-58 to +185°F)
5-95% relative humidity
b
Method 3, 21 days
2000 m/70 kPa
20 years according to IEC/TR 62380
RedFox-5528-F4G-T24G-HV: 381,000
hours
RedFox-5528-F4G-T24G-LV: 371,000
hours
RedFox-5528-F16G-T12G-HV: 397,000
hours
RedFox-5528-F16G-T12G-LV: 386,000
hours
RedFox-5528-T28G-HV: 366,000 hours
RedFox-5528-T28G-LV: 356,000 hours
RedFox-5528-F4G-T24G-HV: 667,000
hours
RedFox-5528-F4G-T24G-LV: 643,000
hours
RedFox-5528-F16G-T12G-HV: 735,000
hours
RedFox-5528-F16G-T12G-LV: 706,000
hours
RedFox-5528-T28G-HV: 643,000 hours
RedFox-5528-T28G-LV: 620,000 hours
2 g rms 5-500 Hz, 5 sweeps
12 dB/octave, 2-13.2 Hz, 0.011 g
13.2-100 Hz, 1.0 grms, 150 minutes per
axis
2
5-2000 Hz, rms 2.3 m/s
30 g, 11 ms
Fire enclosure
3.8 kg
IP40
a
2
/Hz,
,1.5h