Omron MicroHAWK ID-40 Technical Note page 7

360 barcode reading to omron nj/nx controller

Advertisement

2.6.1.
Click the gear icon > Advanced > Communications as shown below.
2.6.2. Set the IP addresses and subnets to the values listed below:
Reader 1 = 192.168.250.11, subnet 255.255.255.0
Reader 2 = 192.168.250.12, subnet 255.255.255.0
Reader 3 = 192.168.250.13, subnet 255.255.255.0
Reader 4 = 192.168.250.14, subnet 255.255.255.0
Reader 5 = 192.168.250.15, subnet 255.255.255.0
Reader 6 = 192.168.250.16, subnet 255.255.255.0
2.7.
Click the Save button to save the changes to the reader. You should receive a warning stating, "Saving
the current settings on your camera will require a reboot. Continue?" Click "OK".
2.8.
Repeat steps 2.1 to 2.7 for Readers 2 through 6.
2.9.
Change the PC's IP address to 192.168.250.101, subnet 255.255.255.0.
2.10.
Disconnect power to all the ID-40 readers and wait 10 seconds.
2.11.
Connect the ID-40 reader's Ethernet cables to the Ethernet switch.
2.12.
Re-connect power to the ID-40 readers. Wait 30 seconds for the readers to boot.
2.13.
Using your PC's internet browser, type the IP address for reader 1 and make sure the PC connects
to WebLink.
2.14.
Save the reader's settings to a file. Click the gear icon > Advanced > Save.
2.15.
Repeat steps 2.13 and 2.14 for all remaining ID-40 readers.