Technical Note: MicroHAWK ID-40 360
11.6.
SYSMAC Studio may display the message seen below if it is currently in Run Mode. Click "Yes" to
continue the transfer.
11.7.
The transfer may take up to 1 minute. Once synchronization is completed, you will see the
Synchronization window. Click "Close".
11.7.1.
After changing the IP address of the NJ/NX controller, SYSMAC Studio may not be able to
communicate with the controller and you may need to wait for SYSMAC Studio to respond.
Go to the section "Omron NJ/NX Controller Ethernet Connection via a Hub" to re-establish
the network connection with the controller.
Configure EtherNet/IP Devices into SYSMAC Studio
Import ID-40 EDS File
12.
Import ID-40 EDS file
12.1.
In the Tools menu, click "EtherNet/IP Connection Settings" as shown below.
12.2.
This opens the EtherNet/IP Device List. Right-click the "Node Address" of the PLC and select "Edit" as
shown below.
18
Barcode Reading Solution
º
TECHNICAL
NOTE