Section 9
Pouring Both
TS = TN = OPEN
&&
!KE
&&
PS = NORMAL
ANY
Cleaning Mode
Switch Hold >= t
&&
!KE
&&
PS = NORMAL
ANY
Keg Change
Keg Empty
LED == OFF
Pump == OFF
SVs == CLOSED
Part Number 020007115 06/27/2019
Pouring Both
TS = TN =CLOSED
TS = OPEN
TN = CLOSED
Not Pouring
Cleaning Mode
cp
*From any
cleaning
state
Switch Hold* >= t
ap
Switch Hold >= t
ep
KE && T <= t
pni
Purge NI
LED == ON
Pump == OFF
SVs == OPEN
KE && T > t
pni
NI = FULL || DEC
NI = EMPTY || INC
KE
TS = CLOSED
TN = OPEN
Pouring Nitro
Pouring Still
T <= t
Flood NI
LED == ON
Pump == ON
SVs == CLOSED
KE && T <= t
fni
ERROR
LED == FAST BLINK
Pump == OFF
SVs == CLOSED
!KE
Run to Empty
KE
LED == ON
Pump == ON
SVs == OPEN
Pour
Pump == OFF
SVs == OPEN
NI = FULL
NI Filling
Pump == ON
SVs == OPEN
Keg Empty
Pump == OFF
Keg Change
SVs == CLOSED
fni
T > t
fni
T <= t
ft
Flush Taps
LED == ON
Pump == ON
SVs == OPEN
KE && T<=t
ft
T > t
ft
KE&& T <= t
s
Soak
LED == ON
T > t
s
Pump == OFF
SVs == OPEN
T <= t
Diagrams
s
59
Need help?