Section 8

Total System Refrigerant Charge

This information is for reference only.
n
Refrigerant type and amount varies by model. Machines
may use R-404A or R-290 refrigerant. Always refer to
model/serial plate to identify refrigerant type and
amount.
n
Some 50 Hz models may contain up to 150 grams of R-290
(propane) refrigerant. R-290 (propane) is flammable in
concentrations of air between approximately 2.1% and
9.5% by volume (LEL lower explosion limit and UEL upper
explosion limit). An ignition source at a temperature
higher than 470°C is needed for a combustion to occur.
Refer to nameplate to identify the type of refrigerant in
your equipment.

mmortant
Due to continuous improvements, this information is
for reference only. Please refer to the serial number tag
to verify electrical data. Serial tag information overrides
information listed on this page.
Model
Tyme
ND21TS00
R404A
Part Number 020007115 06/27/2019
Warning
Warning
Cabinet
(System 1)
7.0 oz (198g)