Rebooting An Sp Assembly Into Normal Mode - Dell EMC Unity 480/F Installation And Service Manual

Hide thumbs Also See for Unity 480/F:
Table of Contents

Advertisement

Service Procedures

Rebooting an SP assembly into Normal Mode

Unity 480/F, Unity 680/F, Unity 880/F Installation and Service Guide
86
Figure 81 Sliding the SP assembly halfway into the chassis
3. Pull the black release tab out completely, and slide the rest of the SP assembly
back into the chassis.
The black release tab slides back into the system as it is inserted.
Figure 82 Installing the SP assembly
4. Pull the orange release trigger and push in gently to re-engage the locking
mechanism.
If the black release tab comes out when pulled, the locking mechanism is not
engaged.
Before you begin
If you removed the SP assembly during the replacement, wait about 10-15 minutes
after reinserting the SP assembly into the system to allow the SP assembly to fully
reboot into Service Mode. Ensure that the SP assembly fault LED is flashing
alternating amber and blue (1 hz) before continuing.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unity 680/fUnity 880/f

Table of Contents