Rebooting An Sp Assembly Into Normal Mode - Dell EMC Unity 480/F Installation And Service Manual

Hide thumbs Also See for Unity 480/F:
Table of Contents

Advertisement

Rebooting an SP assembly into Normal Mode

Figure 108 Installing the SP assembly
4. Pull the orange release trigger and push in gently to re-engage the locking
mechanism.
If the black release tab comes out when pulled, the locking mechanism is not
engaged.
Before you begin
If you removed the SP assembly during the replacement, wait about 10-15 minutes
after reinserting the SP assembly into the system to allow the SP assembly to fully
reboot into Service Mode. Ensure that the SP assembly fault LED is flashing
alternating amber and blue (1 hz) before continuing.
Note
If you attempt this task before the SP assembly has completed its automatic reboot
into Service Mode, the attempt to reboot into Normal mode fails.
Reboot the recently serviced SP assembly into Normal Mode using the procedure that
follows:
Procedure
1. Open Unisphere and select Service, then Service Tasks.
2. Under the name of the SP assembly where you installed the new part, select
Reboot and the click Execute.
3. When prompted, enter the service password to put the SP assembly into
Normal Mode.
It may take up to 15 minutes for the system to complete its reboot, and return
to normal mode.
Rebooting an SP assembly into Normal Mode
Service Procedures
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unity 680/fUnity 880/f

Table of Contents