Z : SELECT SDI FORMAT
(Except for HDS-V3232)
Purpose
This menu is used to set the format of signals fed to the
input/output board of DVS-V3232B and DVS-V6464B
with the control terminal.
This setting is available when the manual switch for the
format on each input/output board is OFF.
Setting Procedure
1. Select menu item [Z].
2. Select a channel line using the cursor to be set. (The
channels will be switched by eight channels.
Displayed signal formats that are enclosed by the
round brackets as "(4:2:2)" have been set on the board
and cannot be modified with the control terminal.
3. When [Enter] is pressed, the setting will change
("4:2:2"
"4 fsc NTSC"
4. Press [S] (Table Set), and the content now appeared is
copied to the area of SDI FORMAT TABLE.
5. Press [Ctrl] _ [E] to stop the display and the menu
screen of the secondary station will be displayed.
SELECT SDI FORMAT
DESTINATION UNIT
01 - 08 : 4:2:2
09 - 16 : 4fsc NTSC
17 - 24 : 4fsc PAL
25 - 32 : 4:2:2
33 - 40 : 4:2:2
41 - 48 : 4:2:2
49 - 56 :( 4:2:2 )
57 - 64 : 4:2:2
SWITCHING FIELD
F1:FORMAT F2:FIELD S:Table Set Ctrl-E:RETURN TO MENU
Example of Setting Screen
n
Unless pressing [S], the data will be deleted when the
power is turned off.
ROUTING SWITCHER SYSTEM (E)
"4 fsc PAL").
DVS-V6464B V2.10 STATION NUMBER 1
SOURCE UNIT
01 - 08 : 4:2:2
09 - 16 : 4:2:2
17 - 24 : 4:2:2
25 - 32 : 4:2:2
33 - 40 : 4:2:2
41 - 48 : 4:2:2
49 - 56 :( 4:2:2 )
57 - 64 : 4:2:2
FIELD
5-2. Setting Items of the Secondary Station
Operating Function Keys
[F1] : FORMAT (Mode which sets the signal format by 8-
channels)
[F2] : FIELD (Mode which sets the crosspoint switching
field)
1. Press [F2]. The cursor will move to "SWITCH
ING FIELD" in the menu.
2. Press [Enter]. The setting will change.
(ODD
EVEN
All switching field in the switcher are deter
mined by this setting.
n
To use RS-422A and S-BUS together, set the switching
field as follows.
1 When using the S-BUS and CART protocol together :
ODD
2 When using the S-BUS and PRODUCTION
SWITCHER protocol together : FIELD
Note that the switching timing of the CART will not be
accurate if the CART and PRODUCTION SWITCHERS
protocols are used together.
Switching timing is not guaranteed in the combination of
different switching fields.
For details of the signal switching timing, refer to "5-8.
Signal Switching Timing".
FIELD
ASYNC
ODD)
5-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents