3. INSTALLATION DESIGN AND PLANNING INFORMATION
3.1.
IMPORTANT NOTICE
(a) The boiler is supplied in one pack. The flue and fixing jig are supplied separately.
(b) This boiler is for use on G20 natural gas only. The boiler is certified to the current issue of EN483 for
performance and safety. It is important that no alteration is made to the boiler, without written
permission of Gledhill Ltd.
(c)
Where no British Standards exist, materials and equipment should be fit for their purpose and of
suitable quality and workmanship.
(d) The installation of this boiler must be carried out by a competent person e.g. CORGI Registered
installer, must comply with the relevant requirements of : -
Manufacturer's instructions supplied
The Gas Safety (Installation and use) Regulations, The Building Regulations and local Water
Company Bylaws. The Health and Safety at Work Act, Control of Substances Hazardous to Health,
The Electricity at Work Regulations and any other applicable local regulations.
The detailed recommendations are contained in the current issue of BS 5440 Pts. 1 & 2; BS 5449;
BS 5546; BS 7074 Part 1; BS 6700; BS 6798; BS 6891, BS 7593, IGE/UP/7/1998
(e) When installing the boiler, care should be taken to avoid any possibility of personal injury when handling
sheet metal parts.
(f)
Refer to Manual Handling Operations, 1992 regulations.
150mm
INSIDE WALL
INSIDE WALL
FIXING FACE
FIXING FACE
CONDENSATE
CONDENSATE
DRAIN
DRAIN
Diagram 3.1 Boiler Models GB30, GB25, GB20
VER: 02.3 _260505
Supplied By www.heating spares.co Tel. 0161 620 6677
730mm
Cut flue terminal at
plain end to length
required allowing
130mm
40mm extra for
85mm
socket elbow joint
F+R
GAS
50mm
360mm
150mm
100mm
100mm
A
A
C
C
BOILER
BOILER
D
D
Centre Line
Centre Line
GAS
GAS
B
B
70 mm
140mm
Clearances From Fixed surfaces
Clearances From Fixed surfaces
Top – From 'A'
Top – From 'A'
Bottom – From 'B' :200mm
Bottom – From 'B'
Sides – From 'C' :20mm
Sides – From 'C' :20mm
Front – From 'D'
Front – From 'D'
FLOW
& RETURN
580mm
C
C
CONDENSATE
CONDENSATE
DRAIN
DRAIN
:220mm
:220mm
:600mm
:600mm