Upload Parameters To The Hot Key - Webasto Frigo Top 10 Workshop Manual

Transport refrigeration
Table of Contents

Advertisement

Fig. 19: Download indication
6.3

Upload parameters to the hot key

Fig. 21: Upload indication
Frigo Top 10 - 43 | Pordoi 2000 - 4000
Fig. 20: End of download cycle
Fig. 22: End of upload cycle
XSwitch on the control element:
– Download starts and the parameters of the hot key
are loaded into the control element.
– The display of the control element shows "doL"
during the download.
– At the end of the download cycle the display shows
"End".
– After 10 s the control element restarts, and uses the
new parameters.
XRemove the hot key.
3 Program the control element as desired with the keys on the front.
3 Leave the control element on.
XInsert a hot key in the slot at the back of the control element.
XPress the "Up" key.
– Upload starts.
– Control element shows "upL".
– At the end of the upload cycle the display shows
"End".
XPress "SET" to finish the upload cycle.
XSwitch off the control element.
XRemove the hot key.
XSwitch the system on again.