10.4 Standard parameter settings

The standard parameter settings differ depending on the refrigerant. The tables below show the standard settings for refrigerant:
■ R134a
■ R134a and system with defrost
■ R404A
Making changes to these settings affects the functional safety of the system. Only make changes to the settings if you are familiar with
the outcome!
10.4.1 Regulation
Label
Description
HY
Differential
LS
Minimum set point
US
Maximum set point
ot
Thermostat probe calibration
P2P
Evaporator probe presence
oE
Evaporator probe calibration
OdS
Outputs delay at start up
db
Dead band (neutral zone)
AC
Anti-short cycle delay
CCt
Continuous cycle duration
CCS
Set point for continuous cycle
COn
Compressor ON time with faulty probe
CoF
Compressor OFF time with faulty probe
10.4.2 Display
Label
Description
CF
Temperature measurement unit
rES
Resolution
Lod
Probe displayed
10.4.3 Defrost
Label
Description
tdF
Defrost type
dtE
Defrost termination temperature
idF
Interval between defrost cycles
MdF
(Maximum) length for defrost
dSd
Start defrost delay
dFd
Displaying during defrost
dAd
MAX display delay after defrost
Fdt
Draining time
dPo
First defrost after start-up
dAF
Defrost delay after fast freezing
Frigo Top 10 - 43 | Pordoi 2000 - 4000
Refrigerant
R134a
R134a with defrost
2
2
0
0
30
30
0
0
y
y
0
0
0
0
n
n
1
1
0
0
0
0
15
15
30
30
Refrigerant
R134
R134a with defrost
°C
°C
dE
dE
P1
P1
Refrigerant
R134
R134a with defrost
EL
in
2
5
1
3
8
5
0
0
dEF
dEF
1
1
1
1
n
n
0
0
Program level
R404A
1
2
2
2
-20
1
30
1
0
2
y
1
0
2
0
2
n
2
y in case of
heating kit
1
2
0
2
0
2
15
2
30
2
Program level
R404A
1
2
°C
2
dE
2
P1
2
Program level
R404A
1
2
in
2
5
1
3
1
5
1
0
2
dEF
2
1
2
1
1
n
2
0
2
16