Parameter Settings In 1St / 2Nd Level Menus; Entering The 1St Service Level; Entering The 2Nd Service Level; Change A Parameter Setting - Webasto Frigo Top 10 Workshop Manual

Transport refrigeration
Table of Contents

Advertisement

4

Parameter settings in 1st / 2nd level menus

Fig. 04: Level 1 parameter in service
level 2
4.1

Entering the 1st service level

Fig. 05: First parameter of the 1
level service menu
4.2

Entering the 2nd service level

Fig. 06: 2nd level service menu
4.3

Change a parameter setting

Fig. 08: 2nd level service menu
4.4

Exit a service menu

Frigo Top 10 - 43 | Pordoi 2000 - 4000
st
Fig. 07: First parameter of the 2nd
level service menu
Fig. 09: First parameter of the 2nd
level service menu
For more information and overviews:
■ Chapter „10.3 Parameter description"
■ Chapter „10.4 Standard parameter settings"
For sake of overview the parameters are grouped per function:
1. Regulation
2. Display
3. Defrost
4. Fans
In service level 2 the decimal point is on to show that the parameter
is a level 1 parameter.
Parameters can be moved from one level to the other,
but it is better to keep the parameters in their original
level.
XPress "Set" and "Up" to move a 2nd level parameter
to service level 1 and visa versa.
+
XPress "Set" + "Down" and hold for 3 seconds.
SET
– The menu shows "LS", the first parameter of the 1
service level.
– The degree symbol starts blinking.
+
XPress "Set" + "Down" and hold for 3 seconds.
SET
– The menu shows "LS" (First parameter of the 1
service level).
– The degree symbol starts blinking.
XPress "Set" + "Down" again and hold for 7 seconds.
+
SET
– The menu shows "Pr2" (2nd service level).
XRelease the keys.
– The menus shows "HY", the first parameter of the
2nd service level.
XEnter the desired service menu.
XSelect the required parameter with the "Up" or
"Down" key.
XPress "Set".
SET
XSelect the required value with the "Up" or "Down"
key.
XPress "Set" to store the selected value.
SET
+
XPress "Set" + "Up" and hold for several seconds.
SET
or
XWait 15 s without pressing a key
A set value is stored even when you exit the service
menu by means of waiting 15 s without pressing a key.