10 Annex

10.1 Technical data

Description
Power supply
Power consumption
Protection
Frontal protection
Digital input
Relay outputs:
Compressor
Defrost
Fan
71
29
Fig. 23:
Control element dimensions
10.2 (Typical) 12/24 VDC wiring and connections
Max.
16 A
1 2 3 4 5
Fig. 24: Wiring connections
Frigo Top 10 - 43 | Pordoi 2000 - 4000
Data
12/24 VDC
3 VA
IP20
IP65
Potential free contact
8(3) A, 16(6) A, or 20(8) A,
250 VAC
8(3) A, 250 VAC
8(3), 250 VAC
60
F
74
9 10 11 12
7 8
13
Description
Operating temperature
Storage temperature
Relative humidity
Measuring and regulating
range:
NTC probe
PTC probe
32
Legenda:
1. Line
2. Defrost
3. Not connected
4. Fan
5. Compressor
6. -
7. Supply 12/24 V
8. Supply 12/24 V
9. Digital input
10. Evaporator temperature sensor
11. Common
12. Room temperature sensor
13. Hot key plug
Data
0 – 60 °C (32 – 140 °F)
-30-85 °C (-22 – 185 °F)
20 – 80%, non-condensing
-40 – 110 °C (-40 – 230 °F)
-50 – 150 °C (-58 – 302 °F)
11